DVR-530H_UK.book 107 Z8 ??????e??xý~
Uxý9=?p??Â
The Initial Setup menu14
Additional information about the TV system About the input colour system
settingsThe available options of the Input Colour System setting
depend on the Input Line System setting. The table below
shows the different options available.
About the input line system
This recorder is compatible with PAL, SECAM, 3.58 NTSC Input Line SystemBuilt-in tuner External input
and PAL-60 TV systems. The Input Line System and Input
625 SystemAutoAuto
Colour System settings determine how the recorder
treats incoming video signals from an external input or PALPAL
the built-in TV tuner.
SECAMSECAM
Please note the following points when changing the
input line system:525 Systemn/a Auto
" When the current input is a built-in tuner channel
3.58 NTSC
preset, changing the input line system will usually
also affect the input line system of the AV2 (INPUT 1/PAL�60
DECODER) input. However if the AV2/L1 In setting is
set to Decoder, then the L2 input is affected instead.
Additional information about component
" If, when the Input Line System setting is changed, the
screen goes blank (due to incompatibility with your video output
TV), you can switch back by pressing and holding the If you switch the Component Video Out setting to
front panel STOP button then pressing OPEN/Progressive when using a TV that is not compatible
CLOSE (also front panel) while the recorder is with progressive-scan video, you will not be able to see
stopped.anything displayed on your TV. If this happens, press and
hold the STOP button on the front panel, then press
" When you switch the Input Line System setting the
Copy List is erased. If you switch the setting using the PLAY. This will set the recorders video output back to
Interlace.
STOP button and OPEN/CLOSE buttons as
described above, there is no confirmation, so please
use with care.
Compatibility of this unit with progressive-scan TVs
" You cant mix recordings of different TV line systems Consumers should note that not all high-definition television sets
on the same disc.are fully compatible with this product and may cause artifacts to
be displayed in the picture. In case of 525 progressive scan
" When you change this setting, the Input Colour
picture problems, it is recommended that the user switch the
System setting also changes (see below).
connection to the standard definition output (Interlace). If there
are questions regarding our TV set compatibility with this model,
About NTSC on PAL TVplease contact our customer service center.
This recorder is compatible with the following Pioneer displays
Depending on the Input Line System setting and the and monitors
NTSC on PAL TV setting, the signal format output when
the recorder is stopped varies as shown in the table Plasma display
"PDP-503HDE, PDP-433HDE, PDP-434HDE, PDP-504HDE, PDP-
below.
435XDE, PDP-435HDE, PDP-435FDE, PDP-505XDE, PDP-
505HDE, PDP-615EX
NTSC on PAL Output when
Input Line System
TVstopped
625 SystemOffPAL
OnPAL
525 SystemOffNTSC
OnPAL�60
107
En |