ELECTRICAL CONNECTION
? Make sure the appliances are installed ? The appliance must be connected to the
and connected to the electricity supply electricity supply by means of an all-pole
by a qualified technician in accordance disconnect switch with minimum contact
with the manufacturer?s instructions and gap of 3 mm.
in compliance with local regulations?.The appliances must be earthed by law.
? The installer is responsible for the ? corDo rect not use multiple plug adapters or
electrical connection of the appliancesextension leads.
and the observance of the relative safety ? After the appliances have been installed,
prescriptions.the electrical components must be
inaccessible.
Interconnecting control box and
cooktop
? Make sure that the voltage shown on the
rating plate is the same as the power supply
voltage in your home.
The rating plate is on the control box and on
the product description sheet.
? Use a type H05RR-F power cord
(minimum length 800 mm).
? Remove cover (P) and connect the supply
cord to the junction block following the
indications given in the table.
? Attention:The control box is pre-set in the
Factory for connection 1. For any other
connection, please refer to the table here
under.
Supply voltageConductors: Electrical connection
Number and size
3 X 2,5 mm2
1230 V 1N ~ +
4 X 1,5 mm2
2230 V 3 ~ +
4 X 1,5 mm2
3400 V 2N ~ +
? Connect the 3 pole and 4 pole connectors to
the respective connectors on the control box.
The 3 pole connectors (Q) is located at the
rear right hand side of the control box, the 4
pole connect (R)or is located at the left hand
side of the control box (see-figure).
? Connect the yellow/green striped earth wire
()(S) from the cooktop to the screw
located near the 3 pole conn(T).ector
WARNING: DO NOT CONNECT TO THE
POWER SUPPLY BEFORE YOU HAVE
FINISHED CONNECTING THE CONTROL
BOX AND COOKTOP.
? Mount the control box in the kitchen unit.
Make sure the power cord is not entrapped.
88 |