INSTALLATION INSTRUCTIONS
LEVEL UNIT
GENERAL INFORMATION
After placing unit in position, check to make
certain the unit is level side to side and front to
back.
UNPACK
Accurate leveling is essential for proper operation.
Unit should be shimmed so that it is solid as well
as level. The shims should be of hard permanent
type material such as masonite.
If required by sanitation code, seal the cabinet to
the floor with an approved caulking compound.
UTILITIES
REMOVE
2 INTERIOR OBSERVE LOCAL CODES
PACKING
BOTTOM FLAPS
1. Lay carton on rear face and break open bottom
flaps.
WATER 1
2. Set carton upright with all four flaps outward.
.
3. Lift carton up and off of machine.
4. Remove all tape and packaging material from the G
outside and inside of the cabinet.
5. Remove the front grill; take out the screws secur- DRAIN
ing the grill at the bottom and lift if free of cabinet.
3
6. Turn the fan by hand to make certain it moves
freely.
ELECTRICITY 2
LOCATE UNIT
Each installation is unique but will require:
1. A cold water inlet of 6.35 mm (l/d?) OD soft copper
tubing and a shut-off valve.
2. Either a gravity drain system or a sump pump to lift
the water to an existing drain.
3. An electrical branch circuit of 220/240 Volt, 50 Hz, 1
phase, with a 10 Amp delayed action fuse.
T4
FOR THE PLUMBER
AIR FLOW
2
IMPORTANT
OBSERVE LOCAL CODES
1. Place unit so that the front side will be completely
unobstructed, to provide proper air flow. CONNECT TO WATER
2. Area should be well ventilated with temperature
1. Use 6.35 mm (%I?) OD soft copper tubing for the cold
above 15°C (SOOF). Best results are obtained between
water supply.
21°C (70°F) and 32°C (90°F).
2. Provide a convenient manual shut-off valve in the
3. Provision for electricity, water and drain connec-
water Ii ne.
tions should be determined.
3. Position the tubing so it can enter the access hole
4. The unit may be closed in on the top and three
located in the right-hand rear of the cabinet. The
sides, but the front MUST BE unobstructed for air
tubing should extend beyond the cabinet front
circulation and proper operation. Installation
when the cabinet is pushed back into position.
should be such that the cabinet can be moved
See Figure 1.
forward for servicing, if necessary. |