Power supply
Through-the-wall installation
cordWiring requirements
The wall opening measurements should be:
230-volt (207 min. - 253 max.)
Height: 16" (40.6 cm) plus twice the thickness of wood used 1D?"
(0.6 cm)0-12 amps
to build frame.
15-amp time-delay fuse or circuit breaker
Width: 22uD?" (57.5 cm) plus twice the thickness of wood used
to build frame.Use on single outlet circuit only.
Depth: 21D?" (6.4 cm) minimum to 8" (20.3 cm) maximum.
230-volt (207 min. - 253 max.)
C0-16 amps
20-amp time-delay fuse or circuit breaker
A
BUse on single outlet circuit only.
D
Recommended ground method
CThis air conditioner must be grounded. This air conditioner is
A.16" (40.6 cm)C.Wood thicknessequipped with a power supply cord having a grounded 3 prong
B.22uD?" (57.5 cm)D.21D?" (6.4 cm) minimum to plug. To minimize possible shock hazard, the cord must be
8" (20.3 cm) maximumplugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's responsibility to have a
properly grounded 3 prong outlet installed by a qualified electrical
Electrical Requirements
installer.
It is the customer's responsibility:
WARNINGTo contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Electrical Shock HazardQuincy, MA 02269
Plug into a grounded 3 prong outlet.
Power Supply Cord
Do not remove ground prong.
NOTE: Your unit?s device may differ from the one shown.
Do not use an adapter.
Do not use an extension cord.
B
Failure to follow these instructions can result in death, A
fire, or electrical shock.
TESTRESET
Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located behind the front panel on the front flange above A.Reset button
the coil area. B.Test button
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply This room air conditioner is equipped with a power supply cord
cord.required by UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is crushed, the
Power supply
electronics detect leakage current and power will be
cordWiring requirementsdisconnected in a fraction of a second.
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
4 |