Air conditioner cycles on and off too much, or does not cool room in cooling mode.
Check if ...Then ...
The air conditioner is notCheck the cooling capabilities of your room air conditioner. Room air conditioners are
properly sized for your room.not designed to cool multiple rooms.
The filter is dirty or Clean the filter. See page 5.
obstructed by debris.
The inside evaporator andClean the inside evaporator and outside condenser coils. See page 5.
outside condenser coils are
dirty or obstructed by debris.
There is excessive heat orUse a fan to exhaust heat or moisture from the room. Try not to use heat-producing
moisture (open containerappliances during the hottest part of the day.
cooking, showers, etc.)
in the room.
The louvers are blocked.Install the air conditioner in a location where the louvers are free from curtains, blinds,
furniture, etc.
The outside tempture iseraDo not try to operate your air conditioner in the cooling mode when the outside
below 65!F (18!C).temperature is below 65!F (18!C).
The temperature of the roomAllow extra time for the air conditioner to cool off a very hot room.
you are trying to cool
is extremely hot.
Windows or doors to theClose all windows and doors.
outside are open.
The temperature set point isAdjust the temperature set point to a cooler setting. Set FAN SPEED to TURBO.
not at a cool enough setting.
The air conditioner is Install your air conditioner in a more shaded window.
installed on the sunny
side of your house.
Water drips from cabinet into your house.
Check if ...Then ...
The air conditioner is notLevel the air conditioner to provide a downward slope toward the outside (1�2 bubble
properly leveled. The airon a carpenterOs level) to ensure proper drainage. See the Installation Instructions.
conditioner should slopeReposition or shim the cabinet as necessary.
slightly downward towardNOTE: Do NOT drill a hole in the bottom of the metal base and condensate pan.
the outside.
7 |