Electrical Installation Requirements
Installation of this product must conform with local codes
or in the absences of local codes with the current
National Electric Code ANSI NFPA 70.
Cooktop requires a 3-wire 240 volt, 60 hertz, AC circuit
protected by a separate 30 amp circuit breaker or time
Bdelay fuse. Ground cooktop using #10 gauge ground
Gwire attached to burner box.
A
C
Junction Box Location
Power supply enters cooktop under element control
Epanel located in front center of cooktop. Junction box
must be located within 30 inches of power supply entry
D
point.
E
F
A ?30 inches between cooking surface and un-protected wood
or metal cabinet above cooktop. 24 inches between cooking
surface and protected wood or metal cabinet above cooktop.
Cabinet bottom must be protected by at least 1 inch thick
millboard with not less than No. 28 MSG sheet steel, .015 inchPower Supply Entry Point
thick stainless steel, .024 inch thick aluminum, or .020 inch
thick copper.
Power Supply Connection
B ?30 inches minimum
C?18 inches maximum
D?11 inches minimum
E ?31 inches minimum!WARNING
F?Single cabinet installation requires a 36 inch width base
To avoid risk of electrical shock, personal injury, or
cabinet.
death, make sure your cooktop has been properly
G?18 inches minimum
grounded and always disconnect it from main power
Minimum Clearances to Combustible Materialsupply before any servicing.
Securing Cooktop to Countertop
To stop cooktop from being lifted out or sliding in cutout,
!WARNING
secure cooktop according to instructions.
1. Place cooktop in cutout.To avoid risk of electrical shock or personal injury
2. Lift front of cooktop and prop open with rod hinged onwhen connecting copper leads to aluminum house
bottom of cooktop.wiring, use only connectors designed for joining
? Rear of cooktop is hinged.copper to aluminum. Follow connector manufacturer?s
3. Locate holes in each corner of burner box flange.recommendations closely .
4. Drill hole through holes in flange into counter top.
5
? Use size /64-inch drill bit.To avoid risk of electrical shock or personal injury, do
? Do not drill through counter top.not ground through neutral wire if installed in mobile
5. Insert screws provided into holes and tighten untilhome or if local codes do not permit grounding through
cooktop is secure.neutral wire.
5 |