Recessed area or closet installationLaundry tub drain system (view A)
The dimensions shown are for the recommended spacing The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
allowed, except the closet door ventilation openings. The of the laundry tub must be at least 39" (99 cm) above the floor
dimensions shown for the closet door ventilation openings are and no higher than 96" (2.4 m) from the bottom of the washer.
the minimum required.
Floor drain system (view B)
3"The floor drain system requires a siphon break that may be
(7.6 cm)
14" max.purchased separately. See ?Tools and Parts.?
2
(35.6 cm) 48 in.
2
(310 cm )The siphon break must be a minimum of 28" (71 cm) from the
19"
(48.3 cm)bottom of the washer. Additional hoses might be needed.
2
24 in.
2 3"
(155 cm )
(7.6 cm)
28"
0"27" 0" 1" 251D?"4"
39"(71 cm)
(0 cm)(68.6 cm)(0 cm)(2.5 cm) (64.8 cm)(10.2 cm)
(99 cm)
ABC
A.Front view
B.Side view
C.Closet door with vents
AB
Additional spacing should be considered for ease of
installation and servicing.
Electrical Requirements
Additional clearances may be required for wall, door and floor
moldings.
WARNING
Additional spacing of 1" (2.5 cm) on all sides of the washer is
recommended to reduce noise transfer.
If a closet door is installed, the minimum air openings in the
top and bottom of the door are required. Louvered doors with
air openings in the top and bottom are acceptable.
Companion appliance spacing should also be considered.
Electrical Shock Hazard
Drain SystemPlug into a grounded 3 prong outlet.
The washer can be installed using the standpipe drain system
Do not remove ground prong.
(floor or wall), the laundry tub drain system, or the floor drain
system. Select the drain hose installation method you need. See Do not use an adapter.
?Tools and Parts.?
Do not use an extension cord.
Standpipe drain system - wall or floor (views A & B)
Failure to follow these instructions can result in death,
The standpipe drain requires a minimum diameter standpipe of fire, or electrical shock.
2" (5 cm). The minimum carry-away capacity can be no less than
17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm)
A 120-volt, 60-Hz., AC-only, 15- or 20-amp, fused electrical
diameter standpipe adapter kit is available. See ?Tools and
supply is required. A time-delay fuse or circuit breaker is
Parts.?
recommended. It is recommended that a separate circuit
The top of the standpipe must be at least 39" (99 cm) high and no
serving only this appliance be provided.
higher than 96" (2.4 m) from the bottom of the washer.
This washer is equipped with a power supply cord having a
3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
39"mating outlet is not available, it is the personal responsibility
(99 cm)
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
AB
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the
washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
5 |