57
GENERAL PRODUCT SPECIFICATION104S CM23 GSIII
Go to cover page
4.3Image centering deviation (For preset modes only)
With respect to fig. 2, the target relationships are
the following :
|A- B| 6mm|C- D| 6mm
Note : This centering is adjustable by the end-user.
4.4Picture shift control range (For preset modes only)
H-shift range : 10 mm min.
V-shift range : 8 mm min.
4.5Picture tilt
With respect to Fig. 3, Tilt to be measured on extremes of center line from bezel.
|A- B|: 2mm
4.6Geometrical distortions (For preset modes only)
It is acceptable that pincushion, trapezoid, rhomboid,
rotation and various waves distortions must remain within
the limits of tolerance as in fig. 4,
where A = B = 3.0 mm. A+B <5 mm
C=D=3.0 mm. C+D <5 mm
The waviness of any vertical or horizontal shall be less than 1.0 mm over a 50 mm distance.
4.7Image non-linearity pattern with
12 equal blocks along horizontal axis,
9 equal blocks along vertical axis. (see Fig. 1) (For preset modes only)
Overall: 10 % (each horizontal and vertical)
Deviation of Two adjacent block : 6%
X. Max. -X. ave.
H. non-linearity =x 100%
X. Max.
Y. Max. -Y. ave.
V. non-linearity =x 100%
Y. Max.
14" CM2300 GS-III CMTR
TYPE: 104S11/89 (COCA)8639 000 10477
00-02-18BRAND : PHILIPS (54K)
Wiliam Ou2559011
00-02-18