20/21V-L110M
CRT CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT
No. Adjusting pointAdjusting procedure/conditionsWaveform and others
1 CRT CUTOFF1. Switch TV to VIDEO mode, BLUE BACK OFF, with
ADJUSTMENT NO VIDEO signal.
(I2C BUS 2. Press R/C to set Picture Normal condition.3.3 Vdc
CONTROL)3. Connect the oscilloscope to Red OUT from IC801.
(TP47R)
Range: 1 V/Div (DC)
Sweep: 5 msec/Div
1 V
4. Adjust SCREEN VR, so that the tip of signal reach0
3.3 Vdc + 0.1 Vdc.
2 SUB-BRIGHT-1. Call "SUB-BRI" in service mode. (Receive Cross-
NESS hatch pattern with 5 black level windows)
ADJUSTMENT2. Adjust the "SUB BRIGHT" bus data in order that
(I2C BUS the line 1, 2 and 3 have the same darkness
CONTROL) wherelse line 4 is slightly brighter than line 1, 21 2 3 4 5
and 3 and finally line 5 will be the brighter than
line 4.1, 2, 3 are in same black level.
o
3 WHITE BAL-1. Receive the "Monoscope Pattern" signal.# 11,600KX: 0.262
ANCE SERVICE 2. Press R/C to set Picture NORMAL condition.Y: 0.272
MODE ADJ.3. Connect the DC milliammeter between the TP602
(I2C BUS (-) TP603 (+).(MINOLTA COLOR ANALYZER
CONTROL)4. Check Beam current should be around (990mA)CA-100)
5. Set it to service mode and adjust the DRI-G-MH,*NOTE: Above DATA can be UP/
& DRI-B-MH data to have a color temperatureDOWN by volume key.
o
of 11,600K (white).
6. Receive "WHITE" pattern, WITH BURST signal,LOWHIGH
and set BRIGHTNESS Y by generator, to ** 101.8cd/m2115cd/m2
2
cd/m(MINOLTA CA-100) by reducing LUMINATE
o
Y signal.*11,600K
o
7. Adjust "CUT-R" & "CUT-G" to get 11,600K. ThenDRI-GW="DRI-GS"DATA-5
go back NORMAL mode (HIGH BRIGHT**) toDRI-BW=:DRI-BS"DATA-5
check color temperature. If out of range, back
to (1).
Note: This adjustment must be done after
warming up the unit for 30 minutes or
longer with a beam current over 500mA.
DRI-R-MH=32(FIXED)
DRI-G-MH=33(FIXED)
DRI-B-MH=37(FIXED)
DRI-R-MH=32(FIXED)
4 Maximum1. Receive the "Monoscope Pattern" signal.
beam check2. Press R/C to set Picture NORMAL condition.
3. Connect the DC milliammeter between TP603 (+)
and TP602 (-).
(Full Scale: 3 mA Range)
4. Beam current must be within 990 50 ?mA.
12 |