61833030GB.fm Page 1 Monday, January 31, 2005 12:07 PM
INSTALLATION AS AN EXTRACTOR OR FILTER HOOD
Respect the following minimum distances from the cooktop: 65 cm (electric cookers), 75 cm (gas cookers).
If the installation instructions for a gas cooker specify a greater distance, then this distance must be observed.
The exhaust duct and clamps are not supplied. Installation of the appliance should be carried out by a qualified
technician.
1. Mark a line on the wall, from the cooktop right up to the ceiling, corresponding to the centre-line of the hood.
2. Bearing in mind the minimum heights over the cooktop specified above, mark the height of the hood on the wall with a
pencil. Apply the drilling template to the wall over this mark.
3. Using the template supplied, mark the holes, drill them and insert the rawlplugs, then fit the 2 hooks (if provided) or partly
screw in 2 screws in the top holes.
4. Hang the hood and adjust the position using the adjustment screws on the hooks (if provided).
Note: The hood MUST be secured with a further 2 screws, to be inserted in the top holes and (if provided) with 2 screws
in the bottom holes.
5. Only for some models: mark the bottom holes (and top), remove the hood, drill, insert the rawlplugs (partly screw 2
screws into the top holes).
6. Fix the flue support to the wall as close as possible to the ceiling. For filter hoods, at this stage, also secure the deflector F1
with 2 screws if the flue is provided with top grilles (for flues with bottom grilles, see installation step ?7?).
7. Hang the hood on the wall again and fix in place with the screws. For filter versions (flues with bottom grilles), the deflector
F2 must be fixed in place of the connector collar (model with fixture with 2 screws) or on the connector collar (model with
2 rear couplings and 1 front fixing screw).
Extractor Hood: fumes are extracted and expelled to the outside through an exhaust duct fixed to the collar at the top of the
hood.
Caution! If the hood is equipped with a carbon filter, this must be removed.
Exhaust air must not be conveyed through a flue used for removal of fumes produced by gas combustion appliances or other
combustible materials, but must have an independent outlet. All national regulations governing extraction of fumes must be
observed.
Filter Hood: the air is filtered by a carbon filter and recycled into the surrounding atmosphere.
Caution! If the hood is not already equipped with a carbon filter, one must be ordered and fitted prior to use.
Installing the electronic control box
? If your hood has an electronic control box, S2 click it into its housing S1 and fix it in place with screw.
? On models with electronic control panels, fit the card S3 in the socket alongside the control box S2.
Installing the telescopic flue
? Connect the hood to the mains supply and fix the telescopic flue to the flue bracket with two screws. Slide the bottom
section down into its seat on the top of the hood. Fit the side grilles if provided.
* Only present on some models
5019 618 33030
D GBFNLEPIGR SN DK FIN |