INSTALLATION
5) ELECTRICAL CONNECTION- Please do not use in the connection any
The electrical connection must be done inreduction, adaptation that may provoke a false
accordance with all electrical and installationcontact following dangerous overheatings.
requirements of the Regulation.- The outlet must be accessible after the built-in.
Before proceeding with the connection, please,When the connection has been done directly to
verify that:
- The power of the electrical system and the powerthe input system:
of the outlets is adequate to the maximum power- Install between the appliance and the system an
of the appliance (see the identification label in theomnipolar switch, adequate to the load of the
lower part of the body).appliance, with a minimum nose between the
- The electrical system must be earthed accordingcontacts of 3 mm.
to the Regulations. We disclaim all- Keep in mind that the ?earth? cable does not have
responsabilities for not observing such points.
- If the appliance is not equipped with an inputto be interrupted by the switch.
- In an alternative solution the electrical connection
cable, connect to the clamp with an adequatecan also be protected by a differential switch with
sized cable (see scheme paragraph 8) keepinghigh sensitivity.
the ?earth? conductor longer than ?live? ones,
following the scheme of fig. 13-14.We recommend to fix the earth coloured cable to an
When the connection to the input system hasappropriate earth installation.
been done through a outlet:WARNINGS:
- Apply to the input cable ?C?, if unprovided, a
normalized plug adequate to the load indicated inAll our products are projected and built
the identification label. Connect the cablesaccording to the European Norms
according to the scheme of fig.13-14, making sureEN 60 335-1 and EN 60 335-2-6 and relative
to respect the undermentioned respondences:amendments.
Letter L1 ( Live ) = cable red colour;The appliance has been produced according
Letter L2 ( Neutral ) = cable black colour;with the European Directives:
Symbol ( Ground ) = cable green - yellow- CEE 89/336 + 92/31 + 93/68 concerning the
colour.compatibility electromagnetic.
- The input cable has to be located so that it never- CEE 73/23 + 93/68 concerning the electrical
reaches a temperature over 75° C.security.
4 HEATING ELEMENTS2 HEATING ELEMENTS
FIG. 13FIG. 14
8 |