Setup Relating to Operations From the Control Panel
(OPERATION Menu)
YSettings for key frame operations: The following settings can be made for
key frame operations.
a) Auto save: Select whether or not, when an effect register is recalled,
the previously recalled effect is automatically saved in its original
register.
ENBL: Save.
DSBL: Do not save.
b) Edit enable auto off: Select whether or not, when an effect register is
recalled, the EDIT ENABLE button is automatically turned off, and
key frame editing disabled.
ENBL: Enable auto off to disable key frame editing automatically.
DSBL : Disable auto off not to disable key frame editing.
YSetting the programmable button function: You can assign functions to
the programmable buttons on the control panel. The programmable
buttons and functions available for allocation are as follows.
Functions assignable to the programmable buttons
Programmable button Functions available for allocation
KEY INV: The KEYNO ASSIGN: No function allocated.
INV button in the keyKEY INVERT ON/OFF: Switches the key invert function
control section ofon or off. (Factory default setting)
each M/E bank (seeMAIN MASK ON/OFF: Switches the main mask on or
page 2-19)off.
SUB MASK ON/OFF: Switches the subsidiary mask on
or off.
EDGE MATTE ON/OFF: Set this to ON to insert a signal
from the dedicated matte generator as key edge fill.
When this is set to OFF, the signal selected on the
utility bus is used for edge fill.Press the button, turning
it on, then adjust matte 1 with knobs 1 to 3: Luminance
(0.00 to 100.00), Saturation (0.00 to 100.00), and Hue
(0.00 to 359.99).
Note
These settings are common to all M/E and PGM/PST
banks. (It is not possible to make independent settings
for different banks.)
(Continued)
13-50Chapter 13Setup |