Troubleshooting
Ice and Water
PROBLEMPOSSIBLE CAUSESWHAT TO DO
No indicator lights Freezer door is not closed.Verify that freezer door is closed. Power is removed
are lit on dispenser from the control when freezer door is opened.
control
Refrigerator is not plugged in.Plug in refrigerator.
Fuse is blown, or circuit breaker needs toReplace any blown fuses.
be reset.Check circuit breakers for any tripped circuits.
Power outage has occurred.Call local power company listing to report outage.
Refrigerator is in Sabbath Mode.See Sabbath Mode, page 15.
Ice or water areFreezer door is not closed.Verify that freezer door is closed. Power is removed
not dispensed from the control when freezer door is opened.
when pads are
select modelsSee Dispenser Lock, page 15.
pressed
Water tank is filling.At initial use, there is an approximate one- to two-
minute delay in dispensing while the internal water
tank is filling.
Ice maker has just been installed or aWait 24 hours for ice production to begin or for ice
large amount of ice has been used.maker to restock after emptied.
Water filter is clogged or needs to beChange water filter (see page 16).
changed.
Ice maker is not Ice maker has just been installed or aWait 24 hours for ice production to begin or for ice
producing enough large amount of ice has been used.maker to restock after emptied.
ice or ice is
Water pressure is too low.Low water pressure can cause valve to leak.
malformed
Water pressure must be between 241 to 689 KPA to
function properly.
A minimum pressure of 241 KPA is recommended for
refrigerators with water filters.
Water filter is clogged or needs to beChange water filter (see page 16).
changed.
Ice maker is not Ice maker arm is up.Confirm ice maker arm is down. See Automatic Ice
producing iceMaker, page 14.
Household water supply is not reachingSee Connecting the Water Supply, page 3.
water valve.
Supply tubing has kinks.Turn off water supply and remove kinks.
If kinks cannot be removed, replace tubing.
Water pressure is too low.Water pressure must be between 241 to 689 KPA to
function properly.
A minimum pressure of 241 KPA is recommended for
refrigerators with water filters.
Check freezer temperature.See Temperature Controls,pages 7-9 to adjust controls.
Freezer must be between -18! to -17! C to produce
ice.
Ice bin is not installed properly.See Ice Storage Bin,page 13.
Improper water valve was installed.See Connecting the Water Supply, page 3.
3
Self-piercing and �16�saddle valvescause low water
pressure and may clog the line over time. The
manufacturer is not responsible for property damage
due to improper installation or water connection.
Water filter Water filter needs to be replaced.If filter is not available, replace with bypass filter.
indicator light is See Water Filter,page 16.
redFilter indicator sensor needs to be reset.See Filter Status Indicator Light, page 15.
Cont.
26 |