Electrical Requirements
ELECTRICAL
For Your Air Conditioner
n REQUIREMENTS
A
BELOW ARE ELECTRICAL PLUG
VARIATIONS. CHOOSE THE ONE WHICH For 115 volt models with serial plate amperes
MATCHES THE AMPERE RATING OF up through 7.5.
YOUR UNIT. THE NUMBER OF AMPERES
IS PRINTED ON THE SERIAL LABEL, OBSERVE ALL LOCAL GOVERNING CODES
ATTACHED TO THE FRONT OF THE UNIT, AND ORDINANCES
BEHIND THE FRONT PANEL (SEE PAGE 2).
Do not, under any circumstances, remove the
power supply cord ground prong.
Chart-A
RECEPTACLE WIRING
RECEPTACLE WIRING should be at least as
large as 14 gauge. Use copper wire only. It is the
personal responsibility and obligation of the
SPRONG customer to provide proper and adequate
GROUNDING PLUG
receptacle wiring installed by a qualified electri-
I cian. OBSERVE NATIONAL ELECTRICAL
n CODE AND ALL LOCAL GOVERNING
3. PRONG CODES AND ORDINANCES.
GROUNDING A
TYPE WALL
RECEPTACLE For 115 volt models with
serial plate amperes up Electrical Requirements
POWER SUPPLY CORD through 7.5
A 115 volt (103.5 min., 126.5 max.) 60 hertz AC
only, 15 ampere fused electrical supply is re-
quired (time delay fuse or time delay circuit
breaker required.). It is recommended that a
separate circuit, serving only this appliance, be
provided. Do not use and extension cord.
For 230 volt and 23Ol208
volt models with serial Electrical Connection
plate amperes up through
Electrical Ground is Required on this Appliance
RECOMMENDED GROUNDING METHOD
RECEPTACLE
For your personal safety, this appliance must be
grounded. This appliance is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in
For 230 volt and 2301206
accordance with the National Electrical Code
volt models with serial
and local codes and ordinances. If a mating wall
plate amperes up through
receptacle is not available, it is the personal
16.0
responsibility and obligation of the customer to
have a properly grounded 3-prong wall receptacle
installed by a qualified electrician. See Figure 1
on page 4. |