Setup menus
<INTERFACE>
No./ItemDescription of settingNo./ItemDescription of setting
200For selecting whether to operate two or 209moreFor setting whether or not to return the ACK
VTRs in synchronization.code when a command is received from RS-
PARA RUN0000DIS: The VTRs are not operated RETURN ACKin232C.
synchronization.0000OFF: The ACK code is not returned.
0001ENA: The VTRs are operated in0001ON : The ACK code is returned.
synchronization.212For selecting the remote control connector
<Note>
To operate the VTRs in synchronization, set all thefor controlling the slave machine when this
VTRs to 1 (ENA). (Refer to pages 14 and 19.)MASTERVTR is to be used as the master machine for
PORTdeck-to-deck operations.
202For setting what ID information is to be0001 IN/OUT: The IN/OUT connector is used.
returned to the controller.
0001OUT: The OUT connector is used.
ID SEL0000 OTHER<Note>
0001 DVCPRO
This setting takes effect only when the 9P button has
0002ORIGbeen set to LOCAL (LED off).
<Notes>
" For 0 (OTHER), the ID information of VTRs other than
DVCPRO models is set.
" Select 2 (ORIG) only when the VTR is connected to a
Panasonic controller (such as the AJ-A900, an
optional accessory).
" Select 1 (DVCPRO) or 2 (ORIG) if the 23/24 Hz mode
has been selected by system menu item No.25
(SYSTEM FREQ).
204For selecting whether the RS-232C connector
is to function.
RS232C SEL0000OFF: The RS-232C connector does
not function.
0001ON: The RS-232C connector functions.
205For setting the RS-232C data transfer speed
(baud rate).
BAUD RATE0000300
0001600
00021200
00032400
00044800
00059600
206For setting the RS-232C data length.
(Unit: bits)
DATA00007
LENGTH00018
207For setting the number of RS-232C stop bits.
(Unit: bits)
STOP BIT00001
00012
208For setting whether the RS-232C parity bit is
to be used and, if it is used, whether even or
PARITYodd parity is to apply.
0000NON :
The parity bit is not used.
0001ODD :
The parity bit is used with an odd parity.
0002EVEN:
The parity bit is used with an even parity.
The underlining (__) denotes the factory setting mode.
87 |