Main Sub
ContentsDetails of function/operation
codecode
2630CE mark support control ON/[Function]
OFF (CE MARK)When this test command is executed, the current set CE mark support control is displayed. Enter the
code number corresponding to the desired CE mark support control and press [ENTER/START] key
to save the setting.
Code numberSettingDisplay itemRemark
0CE mark support control OFFOFFDefault (100V series)
1CE mark support control ONON
[Operation]
The operation is similar to test command 21-01.
38Cancel of stop at drum life [Function]
over (DRUM LIFE END)When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER/START] key to save the setting.
Code numberSettingDisplay itemRemark
0Stop at drum life overSTOPDefault
1Cancel of stop at drum life overNONSTOP
[Operation]
The operation is similar to test command 21-01.
39Memory capacity check [Function]
(MEM.CHK)When the test command is executed, the currently installed SDRAM of the main unit is displayed.
Code numberSettingRemark
88 MBYTE
[Operation]
1) Memory capacity display
26-39 MEM.CHK
8 MBYTE
40Polygon motor OFF time [Function]
setting (Time required from When this test command is executed, the current setting is displayed. Enter the code number corre-
completion of printing to sponding to the desired setting and press [ENTER/START] key to save the setting.
turning OFF the motor) (LSU
MOTOR OFF)Code numberSettingDisplay itemRemark
00sec0 SEC.
130sec30 SEC.Default
260sec60 SEC.
390sec90 SEC.
[Operation]
The operation is similar to test command 21-01.
42Transfer ON/OFF timing [Function]
control setting (TC ON When this test command is executed, the currently set value of the transfer ON timing is displayed
TIMING)(initial display), and the set value is saved. (Setting range: 0 � 9, Default: 5)
CodeSettingRemark
00 msec
140 msec
2�30 msec
3�20 msec
4�10 msec
50 msecDefault
6+10 msec
7+20 msec
8+30 msec
9+40 msec
The default O5� of transfer ON timing is O330ms passed from PS release.�
When set to O0,� it is the same as setting to O5.�
[Operation]
The operation is similar to test command 21-01.