2. Communication section
Note: These items are factory adjusted when shipping according to
FCC standards. Therefore, do not change the setting in the mar-
ket.
A. Dial test (<FAX mode> SIM 66-14, 16)
(1) Dial pulse transmission test
1) Execute SIM 66-14 in FAX mode.
2) Select the item with the 10-key, and press the [START] key.
3) Set the make time with the 10-key.
The dial is sent with the set value + 26ms.
The sending dial cannot be interrupted.
Soft Initial
SIMSet value
SWvalue
Dial 10 FAX SW 25-40ms SW set value: 0 to 151ms step
pulse PPSmode 1 to 4(14)Make time: 26 to (Binary
make 66-1441msinput)
time
(2) DTMF signal transmission level adjustment
1) Execute SIM 66-16 in the FAX mode.
2) Select the item with the 10-key, and press the [START] key.
1
3) Enter the set value with the 10-key, and press the [START] key.
The sending dial cannot be interrupted.
4) Select the soft SW reflection.
Soft Initial
SIMSet value
SWvalue
DTMF High (FAX SW 64--6dBm SW set value: 1dBm
trans-groupmode) 66-4 to 80 to 21 step
mission 16Transmission (Binary
level(Test level: 0.0 to input)
only)-21dB
High SW 65-+2.0SW set value: 0.5dBm
group 5 to 8dBm0 to 15 step
- Transmission (Binary
Low level: 2.0 to input)
group5.5dB
AR-FX7 ADJUSTMENTS 5 - 2 |