AV21BJ8ENS
AV21BJ8EPS
AV21BJ8EES
AV20BJ8EES
ADJUSTMENTS
ŮŮŮŮ SCREEN ADJUSTMENT
Measuring
ItemTest pointAdjustment partDescription
instrument
SCREENRemoteSCREEN VR1. Enter SERVICE MENU.
adjustmentcontrol unit[On the FBT]2. Press YELLOW key to disable vertical scan.
3. Adjust SCREEN VR. on the FBT for a thin horizontal line like a
figure.
4. Press YELLOW key again to enable vertical scan.
5. Press MENU key to leave service menu.
ŮŮŮŮ IF ADJUSTMENT
Measuring
ItemTest pointAdjustment partDescription
instrument
IF adjustment RemoteIF 11. Enter SERVICE MENU.
control unit2. Select IF 1 with FUNCTION ( / ) key
IF 2
3. Press BLUE key during IF 1 is highlighted, IF 1 and IF 2 values
IF 3
are adjusted automatically by software.
IF 4
4. If the standard is L-prime, IF 3 and IF 4 values are adjustment
automatically when BLUE key is pressed during IF 1 is
highlighted.
ŮŮŮŮ OSD HORIZONTAL POSITION ADJUSTMENT
Measuring
ItemTest pointAdjustment partDescription
instrument
HORIZONTALRemoteOSD1. Enter SERVICE MENU.
POSITION OFcontrol unit2. Select OSD with FUNCTION ( / ) key
OSD3. Adjust the OSD horizontal position with the FUNCTION ( / )
adjustmentSERVICE MENU SCREENkey, which shifts the reference bar on the bottom of the
SERVICE MENU horizontally, so that the OSD is positioned on
the screen center. (X=X?)
Reference bar
XX?
Screen size
14No. 51998 |