Connections
Connection procedure
1.Connect the AW-PS301 AC adapter to the DC 12V IN3 Set the CONTROL OUT connector according to the
connector on this adapter.type of pan-tilt connected and the connection
distance.
Press the MENU+ key (2 iSTART ) to change2.Set the control panel selector switch on this adapter to
B.
the menu setting item.
3.1Connect the PAN/TILT CONTROL OUT connectorWhen OMenu-5 Output-1� appears on the LCD panel,
use the ! #STARTSTOPkeys and selecton the control panel to the PAN/TILT CONTROL IN
connector on this adapter using a 10 BASE-TRS-232C or RS-422 according to the pan-tilt head
(equivalent to UTP category 5) straight cable.system to be connected.
The connection distance can be extended up to 500
meters.Menuj 5Output-1
2 Connect the CAMERA CONTROL OUT connector onRS j 232C RS j 422
the control panel to the CAMERA CONTROL IN
connector on this adapter using a coaxial cable6.When the settings are completed, press the MENU+
key (2 iSTART ) once again to exit the menu(equivalent to 5C-2V).
settings.The connection distance can be extended up to 500
meters.
<Note>7.Set the power switch on the pan-tilt head to ON.
This connection is not possible with the AW-RP301
8.Set the POWER switch on the control panel to ON tocontrol panel as it is not equipped with a CAMERA
control the pan-tilt head system. When an AW-RP505 is
being used as the control panel, select the pan-tilt headCONTROL OUT connector.
system using the CONTROL button on the control3 When a PC is used as the control panel, connect it to
panel.the TO RCB/PC connector on this adapter.
9.When the POWER switch on the control panel is set to4.Set the power switch on this adapter to ON.
5.Dial Up Adapter settingsOFF after control of the pan-tilt head is completed, the
1 Set this adapter to direct mode.power of pan-tilt head system will turn off.
Press the MENU+ key (2 iSTART ) to open
the menu settings.
When OMenu-1 Function� appears on the LCD panel,
use the ! #STARTSTOPkeys and select
Direct (direct mode).
Menuj 1Function
TxRxDirect
2 Select the connector for input of control signals from
the controller.
Press the MENU+ key (2 iSTART ) to change
the menu setting item.
OMenu-4 Input� appears on the LCD panel.
Select the CONTROL OUT connector to be used
using the ! #STARTSTOPkeys.
When control is to be performed from a control panel,
select RS-422 and select RS-232C when it is to be
performed from a PC.
Menuj 4Input
RS j 232C RS j 422
16 |