AH-X079E/X099E
AY-X079E/X099E
1-3 Hot keep*During Cooling / Dry
If the room temperature is in the j or k zone during
heating, the compressor is turned on and off to preventTimer set time
overheating.
Room
Zone Compressor intermittent time
Fan
temperature
J
3 min. on - 3 min. off
Same as Compressor1!C
After "3 min. on - 3 min.off" 1
hour
is repeated 4 times, the
compressor goes off, and
only the fan continues to Timer operation startsStops
K3 min. on - 8 min. off
repeat O3 min. on - 8
min.off�.
1-7 Swing louvre
The louvre is moved by a stepping motor to perform
swing and fixing in the set position.
If the "FLOW DIRECTION" button is prossed during
The fan goes off 30 seconds after the compressor
swing, it will stop. If the "FLOW DIRECTION" button is
goes off.
prossed while it is stopped, it will swing.
1-4 Automatic operation
The operating mode and temperature setting are1-8 Restart control
determined by the room temperature and the externalOnce the compressor stops, this control prevents it
from starting again for 3 minutes. It also prevents
air temperature.
starting for 20 seconds immediately following plugging
External air
into the power outlet.
010183134temperature (!C)
Cooling
1-9One-hour operation
(25uC)
If this button is pressed when operation is
26 Heating
Heating
Heating
Cooling
Cooling
Dry
(24uC)(23uC)(22uC)(26uC)(27uC)stopped, operation will begin and then stop after 1
(Room temperature
- 2!C)hour.
21
If pressed when it is operating, will stop after one
Room
The external air temperature is determined by
temperature
hour.
detecting the temperature of the outdoor heat
(uC)
exchanger.
1-10Full power operation
Immediately begins cooling or heating at
maximum power and air flow. Full power stops
1-5 ON-timer
after 1 hour.
The ON-timer is set by pressing the ON-timer button.
(During heating)
In order to attain the set temperature at the set time,
Operates at setting of 32°C.
the operation starting time is corrected by neuro and
(During cooling)
fuzzy computing one hour before the set time.
Operates at setting of 18°C.
1-6 OFF-timer
1-11Preheat
The OFF-timer is set by pressing the OFF-timer
When heating is stopped, supplies a small amount
button. Operation is as follows:
of power to the compressor to make heating start
Set temperaturemore quickly.
Cooling
By fuzzy computing
Operates when the indoor temperature sensor
Heating
Set the shift up time
and external air sensor detect that the room
Cooling setting + 1!C
temperature and outdoor heat exchange
Final
Heating setting - 3!C
temperature are low (below 18°C and 10°C,
respectively). Stops when the compressor
DrySame as above
chamber temperature rises above 30°C.
(Final setting + 1!C)
Preheat does not operate for 2 hours after heating
*During Heatingis stopped. After that, it goes on for 165 minutes
and then stops for 15 minutes, repeatedly.
Timer set time
At least
165
15
120 min min min
3!CRoom
temperature
1
hour
Air conditioner OFF
Timer operation startsStops
16 |