230 and 230/208 volt models
with amperes up through 12.0
Receptacle wlrlng
Receptade wiring should be a minimum of
14 gauge. Use copper wire only. lt is the respon-
sibility of the consumer to provide proper and
adequate receptacle wiring, installed by a
qualified electrician. Observe National Electrical
Code and all local governing codes and ordi-
nances.
Electrlcal requirements
A 230 volt (207 min., 253 max.), 60 Hz, AC only,
15 ampere fused electrical supply is required
(time delay fuse or time delay circuit breaker
required). ll is required that a separate circuit,
serving only this appliance, be provided.
OR
A 23ORO8 volt (197.6 min., 253 max.), 60 Hz, AC
only, 15 ampere fused electrical supply is
required (time delay fuse or time delay circuit
breaker required). lt is required that a separate
circuit, serving only this appliance. be provided.
ElectrIcal connection
Electrical ground is required on this appliance.
W?JW
groundi Recommended groundlng method
tvpe a
For your personal safety, this appliance must be
grounded. This air conditioner is equipped with a
power supply cord having a Spcong grounding
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding-type wall receptade, grounded in
accordance with the National Electrical Code
(ANSVNFPA 70-latest edition) and local codes
and ordinances. if a mating wall receptacle is not
available. it is the responsibility of the customer to
have a properly grounded 3pmng wall receptacle
installed by a qualiii electrician.
Gmrding
m
5 |