[White Balance Adjustment]
Note: Perform the landing adjustment and the digitalxy(cd/m2)
uniformity adjustment before the white balance2832972.7 (low)D93
adjustment as much as possible. (Only in 24 inch)283297100 (high)
1. Outline of Adjustments and Calibration of the Color3133292.7 (low)
D65
Analyzer Used for Adjustments313329100 (high)
Perform the following adjustments.3313462.7 (low)
D56
1.1 Obtaining the Parameters for Converting the RGB331346100 (high)
Drive Voltage of the CRT to the Chromaticity Coordinate
2. Preparations for Adjustments
This monitor comes equipped with a function to copy
color temperature between several monitors.2.1 Input the HD signal (1125) into the G/Y input terminal
Since the CRT drive voltage depends on each individ-of the BK board to display it on the screen.
ual CRT. The same color temperature cannot be2.2 Connect the RS-232C terminal of CA-100 and the
obtained even if the same drive voltage is supplied toOPTION terminal of the monitor using the cables
several monitors. Consequently, to copy a certain colorindicated at Required Tools and Measuring Instru-
temperature between several monitors, there is a needments (see page 3-1).
2.3 Set CA-100 as follows, and attach the measuring probe
to transmit data which does not depend on the CRT
using the xyY chromaticity coordinate.of CA-100 to the center of the CRT screen.
Display mode : xyY mode
When the SYSTEM/COLOR TEMP/FACTORY ADJ
menu of the MAINTENANCE menu is selected andBaud Rate: 9600
executed, the D93 color temperature will automatically
be adjusted, and at the same time, the parameters for3. Select SET UP menu of MAINTENANCE menu.
converting the drive voltage and chromaticity coordi-4. Select the SYSTEM/COLOR TEMP menu of the
nate will be created. Use these parameters whenMAINTENANCE menu.
copying color temperature to other monitors and5. Select D93 of COLOR TEMP, cover the CRT screen
with a blackout cloth, select FACTORY SET, and start
copying color temperature to the memory card.
automatic adjustments.
6. Select D65 of COLOR TEMP, and then select the
PROBE menu. After selecting D65, cover the CRT
screen with a blackout cloth, and select START to start
automatic adjustments.
7. Select the SYSTEM/COLOR TEMP/COPY/OTHER
CRT Drive VoltageCRT Drive Voltage
VALUE menu of the MAINTENANCE menu.
8. Select STD of COLOR TEMP, select D65, and copy
ChromaticityChromaticitythe color temperature data to STD.
coordinatecoordinate9. Select COLOR1 of COLORTEMP, select D93, and
Data transmissioncopy the color temperature data to COLOR1.
10. Select COLOR2 of COLORTEMP, select D65, and
Fig. 1-26copy the color temperature data to COLOR2.
1.2 D65 Color Temperature Adjustment11. Select AUX of COLORTEMP, select D65, and copy
the color temperature data to AUX.
1.3 Copying Color Temperature Data D93 to Color
Temperature STD, COLOR1, COLOR2, and AUX
. Calibration of color analyzer
Generally, when measuring the color temperature of a
certain monitor using several color analyzers, these color
analyzers will show different measured values. The
measured values will also change with time.
Use the color analyzers for this adjustment after calibrat-
ing them so that they will show the correct measured
values at the following chromaticity coordinate.
3-14BVM-D20F1A/D20F1E/D20F1U/D24E1WA/D24E1WE/D24E1WU |