CCB-M series
SPECIFICATIONS
Durability
ItemConditionsSpecifications
VibrationOnly endurance conditioning by a frequencyNo distinct looseness of terminals
sweep shall be made.or visible deformation.
The entire frequency range, from 10Hz to 55HzElectrical characteristics shall be
and return to 10Hz shall be transversed in 1 minsatisfied.
with an amplitude (total excursion) of 1.5mm.
This vibration shall be applied for a period of
2h in each of 3 mutually perpendicular axes
(a total of 6h).
Refer to IEC Pub. 68-2-6 for other procedures.
ShockPeak acceleration : 40GNo distinct looseness of terminals
Duration of pulse : 6msor visible deformation.
Three successive shocks shall be applied in bothElectrical characteristics shall be
directions of 3 mutually perpendicular axessatisfied.
(a total of 18 shocks).
Refer to IEC Pub. 68-2-27 for other procedures.
ColdThe specimen shall be stored at a temperatureNo distinct looseness of terminals
of -25?3uC for 6h and then subjected toor visible deformation.
standard atmospheric conditions for 1h.Electrical characteristics shall be
After this procedure, measurements shall be made.satisfied.
Refer to IEC Pub. 68-2-1 Test Ab for other
procedures.
Dry heatThe specimen shall be stored at 85?2uC for 6hNo distinct looseness of terminals
and then subjected to standard atmosphericor visible deformation.
conditions for 1h.Electrical characteristics shall be
After this procedure, measurements shall be made.satisfied.
Refer to IEC Pub. 68-2-1 Test Bb for other
procedures.
Damp heatThe specimen shall be stored at 40?2uC andNo distinct looseness of terminals
a relative humidity of 90% to 95% for 96 +4hor visible deformation.
and then subjected to standard atmosphericElectrical characteristics shall be
conditions for 1h.satisfied.
After this procedure, measurements shall be mode.
Refer to IEC Pub. 68-2-3 for other procedures.
Change ofThe specimen shall be subjected to 5 continuousNo distinct looseness of terminals
temperaturecycles, each as shown in the table below.or visible deformation.
Following the final cycle, the specimen shall beElectrical characteristics shall be
stored at standard atmospheric condition forsatisfied.
1h, after which measurements shall be made.
TemperatureDuration
1-25 ?3uC30 min.
2Standard atmospheric10 to 15 min.
conditions
370 ?2uC30 min.
4Standard atmospheric10 to 15 min.
conditions
Refer to IEC Pub. 68-2-3 for other procedures.
NOTE : This data is based on the board each.
In assembled, the data on Shock, Vibration are to be changed according to the housing.
6 |