TROUBLESHOOTING (CD SECTION)
When the CD does not function
When the CD section does not operate When the objective lens of the optical pickup is dirty,this section may not operate.Clean
the objective lens,and check the playback operation.When this section does not operate even after the above step is taken,check
the following items.
Remove the cabinet and follow the troubleshooting instructions.
"Track skipping and/or no TOC(Table Of Contents) may be caused by build up of dust other foreign matter on the laser pickup lens.
Before attempting any adjustment make certain that the lens is clean. If not, clean it as mentioned below."
Turn the power off.
Gently clean the lens with a lens cleaning tissue and a small amount of isopropyl alcohol.
Do not touch the lens with the bare hand.
Y When the turntable fails to stop.
5V
Is from 5 V till 0V down pulse (approx. 300 ms) inputCheck the SW3 and the wiring from the IC601 pin 54 to the
0VNo
SW3.
into the IC601 pin 54 when the turntable is rotating?
Yes
Is there following voltage input on the IC601 pin 54 in the
specific state?Check the SW2(MECHA UP SW) and the wiring from the
When the CD mechanism is moved up: 0VNoIC601 pin 54 to the SW2(MECHA UP SW).
In other states: 5V
Yes
Check IC2 pin26 Q91 and Q93 and the periphery.
Yes
IC601 defective.
Y When turntable fails to move.
Is there following voltage input on the IC601 pin 54 in the
specific state?Check the SW2(MECHA UP SW) and the wiring from the
When the CD mechanism is moved up: 0VNoIC601 pin 54 to the SW2(MECHA UP SW).
In other states: 5V
Yes
Is L output from the IC2 pin 26 during SEC when the disc skip
switch is pressed?Check the wiring of IC2 pin 26 and Q93 BASE .
No
OK
Yes
IC2 defective.
Is 4V output from the Q91 emitter during operation stated
Check Q91, Q93 and the periphery.
above?
No
Yes
Check turntable motor and turntable mechanism.
� 38 � |