5. Remove the CRT with the degaussing coil and the dag ground
braid attached.
NOTE
To remove the four brackets holding the degauss coil from the corners of the CRT, first remove
the CRT from the cabinet, then remove the brackets by pressing the tab on the bracket and pull
upwards. These brackets are included in the degauss coilkit, for part number, please see parts
list section
Brackets removal
6. Note the original locations and mounting of the degaussing coil
and the dag ground assembly to insure proper reinstallation on
the replacement CRT.
To remove and remount the degaussing coil:
- Unhook the coil spring from the bottom corners of the CRT
ears.
- Release the braid loop from the upper corners of the CRT ears.
7. Mount the dag ground braid on the replacement CRT. Position the
degaussing coil with new ties.
Dress coil as was on the original CRT.
8. Replace the components on CRT neck and reinstall into cabinet.
Verify that all ground wires and circuit board plugs get connected.
NOTE
Reuse all the clampers and mounting brackets from the degauss coil and screen, and when
remounting the degauss coil assure that is not touching the speakers, this can be done by
placing some tape, this may cause mask vibration. The mounting brackets andclampers are not
supplied with the replacements.
IMPORTANT NOTICE
22 |