10. MAX GAIN Adjustment11. Auto White Balance Standard Data Input
Setting the minimum illumination.SubjectClear chart
If it is not consistent, the image level required for taking subjects in(Color bar standard picture frame)
low illuminance will not be produced (dark).
Adjustment PageF
SubjectClear chart
Adjustment Address20 to 23
(Color bar standard picture frame)
Measurement PointDDS display of LCD or TV monitor
Note 1:Perform OColor Reproduction Adjustment� before this adjustment.
Measuring Instrument (Note)Note 2:Check that the data of page: 6, address: 02 is 00. If not, turn the
power of the unit OFF/ON.
Adjustment PageF
Adjustment Address2C
Adjusting method:
Specified Value70 to 78 (NTSC)1) Select page: 6, address: 00, and set data: 01.
6C to 74 (PAL)2) Wait for 2 seconds.
3) Select page: 6, address: 01, and set data: 11, and press the
Note:The right two digits of the display data at the right bottom side ofPAUSE button of the adjustment remote commander.
the LCD and TV monitor is the object data.4) Select page: 6, address: 01, and set data: 0D, and press the
CA 00 00XXPAUSE button of the adjustment remote commander.
Object data
(When the standard data is take in, the data will be automatically
input to page: F, address: 20 to 23.)
Switch setting:
5) Select page: 6, address: 02, and check that the data is O01�.
1) STEADY SHOT (Menu display) .....................................OFF
6) Perform OAuto White Balance Adjustment�.
Adjusting method:
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 01.
1) Select page: 6, address: 01, and set data: 00, and press the
2) Select page: D, address: 11, and set data: 12, and press the
PAUSE button of the adjustment remote commander.
PAUSE button of the adjustment remote commander.
2) Select page: 6, address: 00, and set data: 00.
3) Select page: 6, address: 00, and set data: 01.
4) Select page: 6, address: 04, and set data: 01.
5) Select page: 6, address: 40, and set data: 02.
6) Select page: 6, address: 56, and set data: 40.
7) Select page: 6, address: 01, set data: 19 and press the PAUSE
button of the adjustment remote commander.
8) Select page: F, address: 2C, change the data and adjust the DDS
display data (Note) to the specified value.
9) Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1) Select page: D, address: 11, and set data: 10, and press the
PAUSE button of the adjustment remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 6, address: 00, and set data: 00.
4) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
5) Select page: 6, address: 04, and set data: 00.
6) Select page: 6, address: 40, and set data: 00.
7) Select page: 6, address: 56, and set data: 00.
5-14 |