4-3. SERVICE MODE
Note:Before performing the adjustments, check the data of page: 0,
address: 10 is O00�. If not, set data: 00 to this address.
1. Setting the Test Mode2-1. EMG Code (Emergency Code)
Page DAddress 10Codes corresponding to the errors which occur are written in
addresses F4, F8 and FC. The type of error indicated by the code
are shown in the following table.
DataFunction
CodeEmergency Type00Normal
00No error
01Forced camera power ON
10Loading motor emergency during loading02Forced VTR power ON
11Loading motor emergency during unloading03Forced camera + VTR power ON
22T reel emergency during normal rotation
05Forced memory power ON
23S reel emergency during normal rotation
Y Before setting the data , select page: 0, address: 01, and set data: 01.T reel emergency (Short circuit between S reel
Y For page D, the data set is recorded in the non-volatile memorterminal and yT reel terminal)24
by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be30FG emergency at the start up of the capstan
40FG emergency at the start up of the drum
exited even when the main power is turned off.42FG emergency during normal rotation of the drum
Y After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander.
Select page: 0, address: 01, and set data: 00.
2. Emergence Memory Address
Page CAddress F4 to FF
AddressContents
F4EMG code when first error occurs
Upper: MSW code when shift starts when first
F6error occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
occursF7
F8EMG code when second error occurs
Upper: MSW code when shift starts when second
FAerror occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second errorFB
occurs
FCEMG code when last error occurs
Upper: MSW code when shift starts when last error
FEoccurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
occursFF
When no error occurs in this unit,O00� is written in the a data bove
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(F4 to F7). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(F8 to FB). Finally, when the last error occurs, the data corresponding
to the error is written in the last emergency address (FC to FF).
Note:After completing adjustments, be sure to initialize the data of
addresses F4 to FF to O00�.
Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 37, and press the PAUSE
button.
3) Check that the data of page:3, address:02 is O00�.
4) Select page: 0, address: 01, and set data: 00.