Software Operation
Audio Input Interface box
Specifies audio signal to be recorded. Select AES/EBU, SDIF-2, or
Analog in accordance with the format of the digital audio signal input to
the DFR-E3000.
Reference Level box
Selects the reference level of the audio signal to be recorded. When
Analog is selected in the Audio Input Interface box, reference level can be
selected among +4 dBu, 0 dBu, and �10 dBu. When AES/EBU or SDIF-2
is selected, reference level can be selected among �20 dBFS, �16 dBFS,
and �18 dBFS.
Select the appropriate reference level in the Reference Level box.
Sampling Frequency box
When AES/EBU or SDIF-2 is selected in the Audio Input Interface box,
sampling frequency can be selected among 44.056 kHz, 44.1 kHz, and 48
kHz. Since the SDDS format uses sampling freqency of 44.1 kHz, the
internal sampling rate converter converts the input signal when 44.056 kHz
or 48 kHz has been selected.
Player Speed Adj. box
When AES/EBU or SDIF-2 is selected in the Audio Input Interface box,
adjust the sampling freqency using this item. For details, contact your
nearest Sony dealer or service personnel.
Ref. Lock box
OLock� appears when the whole system is operating in sync.
Reference box
Specifies the sync signal to use and selects the format of the signal output
to the VIDEO SYNC OUT connector.
Selected sync signal Signal input from theSignal output to the
REFERENCE connectorVIDEO SYNC OUT
connector
Ext. NTSCNTSCNTSC
Ext. MONOMONOMONO
Ext. PALPALPAL
Int. NTSCNNTSC
Int. MONONMONO
Int. PALNPAL
Frequency of vertical sync signal in each video system is as follows:
Video systemFrequency of vertical sync signal
NTSC59.94 Hz
MONO60 Hz
PAL50 Hz