Input Signal Settings � 712
These settings provide adjustment of the signals input to the
DME-3000 from the source selector.
For the method of selecting the input signals, see page 6-2.
With the second set of soft key indications shown in the SETUP &
DIAG menu, press F2 (INPUT CONTROL) to display the INPUT
CONTROL menu.
712 INPUT CONTROL
Input Button 12
Signal TypeY Digital Y Analog
Xpt Number 34
Signal FormatY SMPTE Y B-CAM 0 Y B-CAM 7.5
TBC CenterY 0H Y 0.5H Y 1H Y 1.5H
Phase Phas 1.23 SC 4.56
H ShiftY Off Y Left Y Right
INPUTSIGNALXPTSIGNALTBCH SHIFT
BUTTONTYPENUMBERFORMATCENTER
INPUT CONTROL menu
F8 (H SHIFT) appears only in composite mode.
The following operation is carried out in this menu.
Making the input signal settings
1Use one of the following methods to display the button
number for the source selector (0 to 63) under the OInput
Button� item.
For details of button numbers when two DVS-V1201 or
BVS-V1201 units are connected together as source selector,
see the figure on page 10-26.
Y Press F2 (u) or F3 (3) to increment or decrement the
number.
Y Press F1 (INPUT BUTTON), then enter the button number
using the numeric keypad.
This selects the signal to which the setting adjustment is to be
made.
(Continued)
Chapter 10 Setup Operations10-23 |