DP-C354/C323/C264/C263/C213
DP-C322/C262
F9 Mode
Service ItemRemarks
Mode
F9Unit 06 RAM 00 Parameter Initialize Resets the Fax and Function
MaintenanceInitializeparameters to default values.
Note: Turn the Power Switch to the OFF,
and back to the ON position to enable
the parameter settings.
01 All Job ClearClears all Jobs stored in Flash Memory.
02 Not Used
03 Shipment SetClears All Jobs, All Preset Data,
Parameter Initialize & Resets the
Counters (Fax). (See Note below)
04 LBP Fuser ResetClears the LBP fuser error.
05 Dept. Counter Clear Clears the Department Counter.
06 Job Log ClearClears the Job Log.
07 Image Box Name Init Initialize the Image Box Name.
07 Firmware00 Update from F-ROM Updates the firmware in the machine
UpdateMaster Cardwith the Master Firmware Card.
01 Update from USBUpdates the firmware in the machine
with the USB.
08
-Not Used- --
09
10 Counter00 SC Counter Restore Restores the SC Counter Information.
Restore01 EC Counter Restore
11 Parameter BackupBackup the Parameter.
12 Parameter RestoreRestore the Parameter.
13 Page Memory SizeDisplays the page memory size (MB).
14 Sort Memory SizeDisplays the sort memory size (MB).
15 Not Used- --
16 Remote00 IP AddressSetting of the Remote Operation Panel
Panel01 Port Number (Tx)Option.
02 Port Number (Rx)
17 Logging00 Off
01 HDD
02 Memory
18 Save Log00 SD Card
01 PC Card
20 Counter 00 SC Counter Backup
Backup To 01 EC Counter Backup
SD
21 Counter 00 SC Counter Restore
Restore 01 EC Counter Restore
From SD
Note:
Resetting Counters during Shipment Set should only be performed on a New Initial Installation with all New
Supplies. If the counters are reset during a shipment set, while using old consumable supplies, the Auto
Quality adjustment compensation values will be affected, and may cause Image Quality issues.
The machine?s Image Quality compensation system relies on certain counters when performing the Auto
379