DVP-NS355/NS501P/NS507P/NS525P/NS575P/NS585P
SECTION 6
TEST MODE
6-1. GENERAL DESCRIPTION6-4. MIRROR TIME ADJUSTMENT
The Mirror Time and IOP measurement allows you to makeTo enter Mirror Time Adjustment, press 5 on the remote
diagnosis and adjustment simply by using the remote commandercommander. The screen will appear as below.
and monitor TV. The instructions, diagnosis results, etc. are given
on the on screen display (OSD).
Mirr time Adjust Menu
The Mirror Time and IOP measurement is required is such events
1. CD MIRR time Check:
where servicing a DVD-Player includes changing the Base Unit
2. DVD MIRR time Check:
(BU). For each new BU to be used with a certain MV-044 board,
3. Threshold:
Mirror Time and IOP measurement need to be carried out.
4. Save to EEPROM
5. Default set MIRR time
6-2. STARTING TEST MODE
[Open] Tray open [Close] Tray close
[0] Return to previous menu
Press the [TOP MENU], [CLEAR], [POWER] keys on the remote
commander in this order with the DVD player in standby mode.
The Test Mode starts, then the menu shown below will be
There are five main commands in the Mirr time Adjust menu as
displayed on the TV screen.
shown in the figure above. The functions of each command are
described in the following page.
Remocon Diagnosis Menu
1. CD Mirr time Check
0. External Chip CheckThis command checks the Mirror time value for CD disc.
1. Servo Parameter Check
2. Drive Manual Operation
2. DVD Mirr time Check
3. Emergency History
This command checks the Mirror time value for DVD disc.
4. Version Information
5. Video Level Adjustment
3. Threshold
Model Name : DPX-xxxx_xxThis command displays the threshold value between CD and DVD
IF-con: Ver. x.xxx (xxxx)mirror time.
Syscon: Ver. x.xxx
4. Save to EEPROM
This command saves an adjusted mirror time value to the EEPROM.
The menu above is the Remocon Diagnosis Menu screen which
5. Default set MIRR time
consists of six main function. At the bottom of the menu screen,
This command will set CD and DVD mirror time to firmware default
the model name and IF-con version. To enter Mirror Time
value.
Adjustment menu, press button 2 on the remote commander to
enter Drive Manual Operation menu. To exit from the Test Mode,
[Open] / [Close]
press the power button on the remote commander.
Pressing the Open / Close button controls the tray for disc change
during mirror time adjustment.
6-3. DRIVE MANUAL OPERATION
[0] Return to previous menu
The Drive Manual Operation menu consists of five main
Press [0] button to return to previous menu.
function. By pressing 2 on the remote commander in the
Remocon Diagnosis Menu, the screen will appear as below.
6-4-1. EXECUTING MIRROR TIME ADJUSTMENT
In order to execute mirror time adjustment, the following standard
Drive Manual Operation
procedures must be followed.
1. Servo Control
2. Track/Layer Jump(1)In standby mode, press [TOP MENU], [CLEAR],
3. Manual Adjustment[POWER] to enter Remocon Diagnosis Mode.
4. Tray Aging Mode
5. Mirr Time Adjust
(2)Select ?2. Drive Manual Operation?.
0. Return to Top Menu
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
5. Video Level Adjustment
Model: DPX-xxxx_xx
IF-con: Ver. x.xxx (xxxx)
Syscon: Ver. x.xxx