Multi-channel operation
For multi-channel operation, only use the free channels in a channel bank.
Before putting the transmission links into operation, we recommend
performing an auto scan.
Scan a receiver for free channels.
Bank 1 2 3 4 Select a channel bank with a sufficient number of free channels.
Free 08 08 03 04
Apply the scan result to all other transmitters and receivers.
Bank5678U
Free 0608020108
Adjusting the sensitivity (transmitters only)
SENSITVia the SENSIT menu, you can adjust the transmitters input sensitivity.
The input sensitivity is adjusted too high when close talking distances,
speakers with loud voices or loud music passages cause overmodulation in
the transmission link. In this case, the SK 300 G2?s yellow LED (AF PEAK) )
will light up and the receivers level display for audio signal AF will show full
deflection (see AF peak indication (SK 300 G2 only) on page 11).
If, on the other hand, the sensitivity is adjusted too low, the transmission link
will be undermodulated, which would result in a signal with high background
noise.
The sensitivity is correctly adjusted when the level display for audio signal
AF shows full deflection only during the loudest passages.
Note:
For monitoring the adjusted sensitivity, the transmitter?s level display for
audio signal AFŽ always indicates the audio level even if the
transmitter is muted.
The following figures are a guide to the best settings:
y Loud music/vocals:?30 to 20 dB
y Presentations:20 to 10 dB
y Interviews: 10 to 0 dB
y Musical instruments:
? electric guitars with single coil pickups:10 to 0 dB
? electric guitars with humbucker pickups:20 to 10 dB
? guitars with active electronics
(active pickups, active EQs, piezo pickups):?30 to 20 dB
30 |