GS-XP07ER�GU-XR07ER
GS-XP09ER�GU-XR09ER
GS-XP12ER�GU-XR12ER
*During Cooling / Dry1-11 Auto Restart
When power failure occures, after power is
Timer set timerecovered, the unit will automatically restart in the
Room same setting which were active before the power
temperaturefailure.
1!C
Operating mode (Cool, Heat, Dry)
1
hour Temperature adjustment (within 2uC range)
automatic operation
Timer operation startsStops
Temperature setting
1-7 Swing louvre Fan setting
The louvre is moved by a stepping motor to perform Air flow direction
swing and fixing in the set position. Power ON/OFF
If the "FLOW DIRECTION" button is prossed during Automatic operation mode setting
swing, it will stop. If the "FLOW DIRECTION" button Swing louver
is pressed while it is stopped, it will swing.Setting not memorized
The vertical adjustment louvre will change its angle Timer setting
continuously. Full power setting
Press the SWING button again when the vertical
1-12 Error diagnostic display
adjustment louvre is at the desired position.(a) Indoor unit
Y The louvre will stop moving within the range shown
(1) If the operation is stopped and the emergency
in the diagram.operation button is pressed down for 5 seconds
Y The adjusted position will be memorized and willor more, the self-diagnosis memory can be
be automatically set to the same position when
recalled.
operated the next time.(2) Details of self-diagnosis (error mode) are
Adjustment rangeinformed by the flashing number as well as the
lighting pattern of the operation lamp which
COOL and DRY modes
Floor standing Ceiling suspendedflashes with the timer lamp.(For details, refer to
Error diagnostic method.)
1-13 Compressor relay
(1) It is ON during operation, and when operation is
stopped, goes OFF after a delay of 120 seconds
(not immediately).
The adjustment range is narrower the Air conditionerON
SWING range in order to prevent con-operation
densation from dripping.OFF
HEAT modeON
Floor standing Ceiling suspendedCompressor
relayOFF
120 sec.
(2) The minimum OFF time of the relay is 60 seconds.
It will not go ON again before 60 seconds elapses.
The range is wide so the air flow can be
directed toward the floor.Air conditionerONON
1-8 One-hour operationoperationOFF
If this button is pressed when operation is stopped,
ONON
operation will begin and then stop after 1 hour.Compressor
If pressed when it is operating, will stop after onerelayOFF
hour.
120 sec.60 sec.
1-9 Full power operation
Immediately begins cooling or heating at maximum(3) If air conditioner operation is turned on again
power and air flow.during the 120 second delay before the
(During heating)compressor relay goes off, the compressor relay
Operates at setting of 32 uC.will stay on.
(During cooling)
Operates at setting of 18 uC.Air conditionerONON
operationOFF
1-10 Power ON start
If a jumper wire is inserted into the place indicatedON
JP99 on the indoor control board, and the power plugCompressor
relay
is inserted. cooling or heating will be automatically120 sec.
determined by the room temperature sensor on the
main unit, and operation will begin.
15 |