(5) Interface Transport Motor* Adjust so that the distance between the lower guide and the
upper guide flapper is 22mm with the solenoid plunger
1) Remove the paper pass unit.
pushed in. Install the entry reverse pass solenoid..
2) Remove the bottom cover. (See (4).)
3) Disconnect the connector, then remove the interface transport
motor.22mm
12
3(7) Entry Roller
1) Remove the paper pass unit.
2) Remove the interface transport motor. (See (4).)
3) Remove the front cover. (See (6).)
4) Remove the stopper band, and the bracket, then remove the
upper guide unit.
(6) Entry Reverse Pass Solenoid.
1) Remove the paper pass unit.
1
2) Remove the bottom cover. (See (4).)
3) Remove the front cover.
3
2
2
* When installing, adjust so that the solenoid is fit with the
4) Remove the solenoid unitbracket ?adjustment reference. If the upper guide unit mag-
net lifts up, adjust the bracket for the magnet not to lift up.
1
Adjustment
reference
? 0.5
2
5) Remove each parts, then remove the entry roller.
5) Remove each parts, then remove the entry reverse pass sole-
noid.
MX-FNX2/AR-PN1/MX-RBX1 DISASSEMBLY AND ASSEMBLY 6 - 12 |