AV-14AM
Measuring
ItemTest pointAdjustment partDescription
instrument
AdjustmentSignal2. HOR.10. Receive a circle pattern signal.
generator
of####HOR.POSITION11. Select 2. HOR POSITION with the MENU 1/2 key.
POSITION12. Set the initial setting value of 2. HOR. POSITION with the
Remote
control unitMENU - / + key.
13. Adjust 2. HOR. POSITION to make H=H" as shown in Fig.3
with the MENU - / + key.
HH"
Fig.3
AdjustmentSignal4. VER. LINEARITYIIII When the vertical linearity has been deteriorated
generator
of VER. LIN.5. VER. SCURVEremarkably, perform the following steps.
& VER.14. Receive a cross-hatch signal.
Remote
SCURVEcontrol unit15. Select 4. VER. LINEARITY with the MENU 1/2 key.
16. Set the initial setting value of 4. VER LINEARITY with the
MENU - / + key.
17. Select 5. VER. SCURVE with the MENU 1/2 key.
TOP
18. Set the initial setting value of 5. VER. SCURVE with the
MENU - / + key.
19. Adjust 4. VER. LINEARITY and 5. VER. SCURVE so that the
spaces of each line as shown in Fig.4 on TOP, CENTER and
CENTER
BOTTOM become uniform.
BOTTOM
Fig.4
20. Make sure that the adjustment is properly done on the screen
of 60Hz mode.
[NOTE]
" Adjust to make both 50Hz & 60Hz are the same v. size and
fine straight line.
" When adjust again, adjust 50Hz mode first.
" When adjust in 60Hz mode, only 60Hz mode is adjust.
24No. 56091 |