AV-14F1P
PURITY, CONVERGENCE ADJUSTMENT
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer.WEDGE
DEFLECTION
YOKE
2. Loosen the retainer screw of the deflection yoke.
P
CRT3. Remove the wedges. (Fig. 1.)
4 6
4. Input a green raster signal from the signal generator, and turn
the screen to green raster.P/C
MAGNETS
5. Move the deflection yoke backward.? P/C MAGNETS
P : PURITY MAGNET
6. Bring the long lug of the purity magnets on the short lug and4 : 4 POLES (convergence magnets)
6 : 6 POLES (convergence magnets)position them horizontally. (Fig. 2)
Fig. 1
7. Adjust the gap between two lugs so that the green raster will
come into the center of the screen. (Fig. 3)
8. Move the deflection yoke forward, and fix the position of the
deflection yoke so that the whole screen will become green.PURITY MAGNETS
Long lug
9. Insert the wedge to the top side of the deflection yoke so that it
will not move.
10. Input a cross-hatch signal.Short lug
Bring the long lug over the short lug
and position them horizontally.
11. Verify that the screen is horizontal.
Fig. 2
12. Input red and blue raster signals, and make sure that purity is
properly adjusted.
(FRONT VIEW)
GREEN RASTER
CENTER
Fig. 3
No. 5608423 |