Item
SymptomCauseRemedy
No.
Received image 1 Are copied image or a test YES Go to item 2.
is too light or image also too light or
Failure in the remote side
faded.faded?
(improper setting of docu-
ment contrast, improper doc-
Note
ument handling, poor line
The following causes may
condition, and error in the
be possible (improper set-NO
transmission unit of the
ting of document con-
remote terminal).
trast): a document with
small blue characters or
file lines
2 Any improvement after YES Replace the imaging unit.
replacing the imaging unit?For details see Copier service
NOmanual ?Image quality prob-
lem.?
Received image 1 Are characters of copied Failure in the remote side
is squeezedimage or a test image also (improper setting of docu-
squeezed? YESment contrast, and error in
Improper setting of docu-the transmission unit of the
ment contrast: Received remote terminal).
image of small characters or Go to item 2.
blue copies with ?contrast?
switch set ?Darker?.
Error in remote machine:
The following causes are
possible:
NO
A. Failure in board of scan-
ner unit
B. Improper adjustment of
optical focus
C. Dew on optical lenses
(Proceed to anti-dew.)
2 Any improvement after YES Replace the imaging unit.
replacing the imaging unit?
For details see Copier service
NOmanual ?Image quality prob-
lem.?
T-11 |