ADJUSTMENT
36 MODE
[1] Setting Method[2] High Voltage Adjustment
This machine is provided with 36 Mode as an adjust-Adjusting the high voltage for charging, transfer, sep-
ment mode.aration, and development.
This mode is used to perform various adjustments.1. Select "1 Process adjustment" in the Adjust-
1. Turn off SW2 (sub power).
ment mode menu Screen to display the Process
2. Turn on SW2 while holding down both paper
adjustment mode menu Screen.
quantity buttons 3 and 6.
The Adjustment mode menu Screen appears.2. Press "1 High voltage adjustment" in the Pro-
At this point, you are in 36 mode and normal copycess adjustment mode menu Screen to display
operation is disabled.the High voltage adjustment mode menu.
[Adjustment mode menu Screen]3. High voltage adjustment consists of the follow-
2 ADJUSTMENT
ing:
1 HV adjustment (Charge)
2 HV adjustment (Transfer)
3 HV adjustment (Separation AC)
4 HV adjustment (Separation DC)
5 HV adj. (Charging grid voltage)
3. Press the number key corresponding to the item6 HV adj. (Bias of development)
to adjust.
7 Transfer guide confirm
The setting screen for each item is displayed.
4. Enter data in each adjustment screen.8 HV adjustment (TGR)
5. If there are several adjustment items, press the4. Press the number key corresponding to the item
to be adjusted.
NEXT or BACK key to select the desired
The adjustment screen of the selected item is
item. If there are more screens below, press the
displayed.
key displayed on screen to change screen.
5. When adjustment completes, the screen returns
6. Enter data and press the SET key if it is avail-to the High voltage adjustment mode menu
screen.
able, to confirm your entry.
6. Press the key in the High voltage
7. Press the RETURN key to end adjustment.RETURN
Adjustment mode menu Screen to return to the
8. Turn off the SW2 and exit the 36 mode.
Process adjustment mode menu Screen.
9. The new adjustment values take effect after
restarting the machine.