DLV-100
4.10 On Screen Display
1. Pull down menu
Basic/Custom menu <> Advanced menu
2. Multilingual menu
English / French /German / Italian / Japanese / Spanish / Swedish
4.11 Remote
Palm type remote unit
4.12 Input current
2.2A 100 ~ 120VAC/1.1A 200 ~ 240VAC
4.13 Plug & Play data
Tab.1 EDID data
0000111122232334344455556667677788889999AAABABBBCCCCDDDDEEEFEFFF
00000000 00 FF FF FF FF FF FF 00 38 A3 D3 00 01 00 00 00
10101010 27 0B 01 02 0E 00 00 78 0A 34 70 95 59 4F 88 26
20202020 15 4A 53 FF FF 80 31 59 45 59 61 59 71 59 81 4F
30303030 81 99 A9 4F 01 01 EA 24 00 60 41 00 28 30 30 60
40404040 13 00 00 00 00 00 00 1E F9 15 20 F8 30 58 1F 20
50505050 20 40 13 00 00 00 00 00 00 1E 00 00 00 FD 00 32
60606060 78 0F 64 0A 00 0A 20 20 20 20 20 20 00 00 00 FC
70707070 00 4F 4E 4B 59 4F 20 44 4C 56 31 30 30 0A 00 E2
4.14 Safety test
(1)Dielectric strength test
By the test vessel, under the condition of main power supply ON,
Apply AC voltage of 1500V(+50/-0) ,at 50Hz or 60Hz for 1.5~2 second between power supply
circuit part(AC) and exposure metal part.
No insulation destruction, catching fire, and so on is allowed.
(2) Insulation resistance test
Measure insulation resistance between power supply circuit part(AC) and exposure metal
part (FG) under the condition of main power ON(Stand By mode) by using 500V insulate
ohmmeter.
Insulation resistance shall be more than 50M ohm.
(3)Leakage electric current test
Measure leakage electric current by the leakage ammeter under the condition of main power
supply ON (Standby condition). The measurement impedance should be measured by
the build in resistor of 1.5K
, with the bypass capacitor of 0.15 F.
The leakage electric current should be less than 2mA each.
4.15 Signal table
Refer to Tab.2. |