Mechanical Instructions FM23, FM24, FM334.EN 23
Shielding frame
Foam cushionFront display
CL 16532099_046.eps
270901
Figure 4-9 Exchanging the glass plate
CL 16532099_047.eps
260901
Exchanging the glass plate
1. Take the monitor from its service stand, and put it (face Figure 4-10 Exchanging the PDP
down) on a soft surface (blanket, foam cushion or foam
stand), to make sure that you do not damage the front glass To exchange the PDP panel:
plate. 1. Take out the SCAVIO panel and Power Supply panel, as
2. Remove the metal back plate as described in paragraph
described earlier.
'Rear Cover Removal'.2. Unscrew all fixation screws of the (metallised) shielding
3. Unscrew all fixation screws of the plastic back cover.
frame (two at the top and two at the bottom, see figure
4. Lift and remove the plastic back cover. 'Exchange PDP').
5. If the triangular shaped cable holder at the left bottom is
3. The shielding frame can now be taken off the PDP.
present, unscrew the fixation screws of the holder at the left 4. Replace the PDP.
bottom, see figure 'Exchange Glass Plate'.
6. Unplug the cable of the LED/Switch panel, connector 0320
7. If the ESM Filter Panel at the left bottom is present, 4.5Re-assembly
unscrew the fixation screws.
8. Unscrew all fixation screws of the (metallised) shielding To re-assemble the whole set, do all processes in reverse
frame, see figure 'Exchange Glass Plate'.order.
9. You can now remove the (metallised) shielding frame,
together with the PDP, Audio panel, Power supply and Notes:
SCAVIO panel attached to it, see figure 'Exchange Glass You must replace the speaker-box sealing foam, in case
Plate'. the plastic rear cover has been (re)moved.
Note: To prevent scratches, make sure to put the shielding While re-assembling, make sure all the cables are in their
frame together with the PDP on a soft surface.original position and make sure all the EMC foams are
10. Replace the glass plate.present to ensure 'EMC tightness'. |