CLEANING31 October 1995
8.3 USED TONER OVERFLOW DETECTION
The CPU uses an overflow counter to detect used toner overflow.
The overflow counter counts the total number of copies since the last time the
toner end counter was cleared. When the overflow counter reaches 60K
copies, the CPU starts to blink "E70" on the operation panel. An additional
250 copies can be made before the Start indicator turns red and copying is
disabled.
After disposing of the toner in the used toner tank, use SP83 to clear the
overflow counter.
Toner end counter clear (SP83)
Setting (SP83)Memory counter
0Not cleared
1Cleared
NOTE: If SP115 is set to 1, the machine uses the optional toner overflow
sensor to detect toner overflow. "E70" blinks when the toner
overflow sensor is actuated, and copying is disabled when an
additional 250 copies have been mode.
2-44 |