Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SHARP AY-X10CR-N Repair Manual

$7.99

SHARP AY-X10CR-N - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
Henry Seiden - 02/26/2009 5 of 5 Stars!
I downloaded this product and looked through it quickly with Adobe Reader v9. It is clean and a good copy. Some scanned pages are not perfectly square, but that is a minor complaint. The document schematics and board diagrams are easy to read, of good contrast. The whole file downloaded quickly. This is a good service! Sony charges about $100 for the printed version of the same manual. It is still available through their print-on-demand pro parts system, but why would you do that?
Jeff Lewis - 07/24/2006 5 of 5 Stars!
Received the Hitachi user manual. Happy happy happy! Thanks again.
Steve Fink - 07/24/2006 5 of 5 Stars!
Nice, really nice. I was happy to receive manual in true electronic form, instead of scanned original. This manual includes: Wiring diagram, circuit diagram, block diagram, PC board, adjustment, exploded view, PARTS CATALOG and more.. It's full color manual, not B&W or grayscale :)
Adam Solitro - 12/24/2007 5 of 5 Stars!
Hi guys, Thank you for the fast and reliable service that your company offers. Great Work :)
Glen Meyer - 10/26/2008 3 of 5 Stars!
Very fast service, manual is well scanned and clear, but the Appendix A containing PC Command table and Control codes are missing

Customers who bought this product also purchased
SHARP 10P16S Service Manual
SHARP 10P16S Service Manual
SHARP 12P17S Service Manual
SHARP 12P17S Service Manual
SHARP 20PL83 Service Manual
SHARP 20PL83 Service Manual
SHARP 14BN1 Service Manual
SHARP 14BN1 Service Manual
SHARP 10P28G Service Manual
SHARP 10P28G Service Manual
SHARP 10P18G Service Manual
SHARP 10P18G Service Manual

Click to see text excerpt from the manual
AY-X10CR
AE-X10CR
AY-X10CR-N
AE-X10CR-N
1-13Auto Restartinformed by the flashing number as well as the
When power failure occures, after power islighting pattern of the operation lamp which
recovered, the unit will automatically restart in theflashes with the timer lamp.(For details, refer to
same setting which were active before the powerError diagnostic method.)
failure.
2. OUTDOOR UNIT
Operating mode (Cool, Heat, Dry)2-1 Defrost operation (AE-X08CR/X10CR/13CR)
Temperature adjustment (within 2uC range)(1) Overview
automatic operation
Defrosting begins during heating if the conditions for
Temperature setting
compressor operation time and outdoor heat
Fan setting
exchanger temperature are met.
Air flow direction
When defrosting begins, the indoor and outdoor fans
Power ON/OFF
stop. Defrosting stops when the temperature of the
Automatic operation mode setting
outdoor heat exchanger goes above approximately
Swing louver
5uC or defrosting time exceeds 13 minutes.
Setting not memorized
Defrost Defrost Defrost
Timer setting
mask timemask timemask time
Full power setting
1-14 Indoor/outdoor temperature display
Heating
Every time the Temperature check button is
begins
pressed on the remote control, the display changesDefrostingDefrosting
in the order of indoor temperature outdoorMax. 13 min.Max. 13 min.
temperature no display. The temperature is
2) Defrosting
displayed on the temperature indicator on the main
If the compressor operation time is more than 20
unit to be referred to for energy saving.
(When the unit is not running, the display changesminutes in the heating mode and the outdoor air
between indoor temperature and no display.)Indoortemperature and outdoor heat exchange temperature
temperature is the temperature of the suction airsatisfy the defrosting conditions, the defrosting
measured by the room thermistor, and outdooroperation is started.
temperature is that measured by the outdoorWhen the outdoor sheat-exchanger temperature
temperature thermistor. When indoor temperature
reaches approx. 7°C or above or when the defrosting
is displayed, the indoor LED on the main unit is lit,
time exceeds 13 minutes, the defrosting operation is
and when outdoor temperature is displayed, the
quit.
outdoor LED is lit. For 90 seconds after the
operation starts, - - is displayed instead of theMore than More than More than
actual outdoor temperature since it is still being
20 min.20 min.20 min.
measured.Because of the effect of the exchanger,
the unit cannot confirm the exact indoor
temperature right after the operation is terminated.
Therefore, for one hour since the operation is
stopped, the indoor temperature immediately before
Heating
the operation is stopped is displayed. After over
operation
one hour since it is stopped, the unit displays the
start
actual room temperature at that point.DefrostingDefrosting
Max. 12 min.Max. 12 min.
1-15 Error diagnostic display
(a) Indoor unit(3) During defrosting
(1) When an error is detected, all relays areWhen defrosting begins, the compressor stops.
turned off. At the same time, the details of theApproximately 1 minute later, the compressor
error are displayed by flashing the numberreactivates in the refrigeration cycle, and the outdoor
corresponding to the type of the error. Theheat exchanger is defrosted.
details can also be displayed by pressing down
Each mode is as follows:
the emergency operation switch for 5 seconds
The outdoor fan is stopped
or more in the state of operation stop.However,
The operating frequency is as shown in the table
if the operation is continued only in the serial
below The indoor fan is stopped.
open state and the state remains unchanged
The 4-way valve is OFF.
after that, the main relay is turned off in 8
minutes. In the serial short state, the error is
not displayed and the operation is continued. Iffor 5 minutesafter 5 minutes
the unit stays in the same state, the main relay
62.50062.500
is turned off in 8 minutes. Although the error is
not displayed, it is memorized and can be
displayed when it is recalled.
(2) If the operation is stopped and the emergency
operation button is pressed down for 5 seconds
or more, the self-diagnosis memory can be
recalled.
(3) Details of self-diagnosis (error mode) are
15
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
RD-XS34SB
RD-XS34SB
Quick Start

$4.99
Current Parse Time: 0.094 s with 42 queries. Queries took 0.010683