Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SHARP FOB1600 Repair Manual

$7.99

SHARP FOB1600 - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English German French


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
Patrick Guice - 04/23/2008 5 of 5 Stars!
Phenomal manual great resoulution and very legible. Will become very helpfull in future for parts and service.
Steve Troake - 10/05/2006 5 of 5 Stars!
Just got this Manual downloaded... Scan is PERFECT! This is EXACTLY what I needed. However, please update your site info to state that it may take more than \"a few hours\" to have the download available after payment - - - I had to wait 4 days, in my case. Otherwise, I am very happy with this!!! Thanks! --- User-Manuals.COM comment We\'re sorry for delay, we had major problem with our download server, but all is ok now and downloads works as previous.
Fabian Castle - 08/01/2006 5 of 5 Stars!
Thanks for the excellent service. The manual arrived quickly and in excellent condition. Quality A+++!
John Craig - 07/31/2006 5 of 5 Stars!
Very nice site and the manual is great. A life-saver. Thank you so much!
Aaron Lawrence - 01/02/2008 4 of 5 Stars!
Contains mechanism diagrams, parts lists and schematics for all worldwide versions of DC-X88Z. Also includes remote schematic etc. A few non-essential pages are missing such as specifications. Includes the mechanical and electronic calibration instructions for the tape decks.

Customers who bought this product also purchased
SHARP 20PL83 Service Manual
SHARP 20PL83 Service Manual
SHARP 25AN1 Service Manual
SHARP 25AN1 Service Manual
SHARP 10P28G Service Manual
SHARP 10P28G Service Manual
SHARP 115U_OM.pdf Service Manual
SHARP 115U_OM.pdf Service Manual
SHARP 10P35G Service Manual
SHARP 10P35G Service Manual
SHARP 10P16S Service Manual
SHARP 10P16S Service Manual

Click to see text excerpt from the manual
UX-B700U
FO-B1600U
6) Sub scanning direction resolution conversion circuit14) FaxEngine bus interface
It reads 1 byte (8 dots in the main scanning direction) of data in the mainIt functions as a bridge connecting the external bus of Fax Engine-LSI
scan 600 dpi data buffer, converts the resolution in the sub scanningand the internal bus of this ASIC. It operates at 1 wait except for the
direction, and stores the data in the sub scan 600 dpi data bufaccesses by the command or response buffer. Thenfer. As these two buffer ac-
it repeats this operation every 8 dots until reaching the end of line.cesses via the arbiter, the external wait will be generated by the RDY
It further converts the data for 208 lines and sends out the completionsignal.
pulse when finished.15) Interruptive controller
In the sub scanning direction, the input data per line may increase up toIt collects causes of interruption that occurs in the ASIC and generates
13 lines and go over the swath. To simplify circuit configuration, apply
the same conversion method to after the 208th line and continue con-interruptive signals when interruption of Fax Engine firmware is prohib-
version up to 220 lines. The lines 209th and over should be handled asited. It clears or retains interruption factors.
the next swath data.16) Memory access arbiter
7) Sub scan 600 dpi data buffer (buffer controller)It adjusts memory accesses from buffers. It possesses 9 access chan-
It performs pointer management to use the DRAM as a buffer for 440nels.
lines (208 + 12 lines x 2).The arbitration logic needs to be devised in order to secure the data
transmission rate.
The buffer cannot be cleared until swath data conversion (printing com-
mand output) is complete as it reads data in the line direction. 17) DRAM controllerTo avoid
degraded performance, this buffer should have a capacity for 2 sets of
swath data. The buffer should store 220 lines per swath due to the con-It accesses memory using read cycle, early write cycle and CAS-before-
figuration of the sub scanning direction resolution conversion circuit.RAS refresh cycle of MSM51V4800E-70 [OKI] of 4Mbit Fast Page DRAM.
8) Printing dot counting circuit/print duty judging circuit
It monitors the output data from the sub scanning direction resolution
conversion circuit and counts the number of black dots. When counting
of a swath (208 lines) is finished, it sends the result to the ESC com-
mand adding circuit to reflect it on the ESC command parameter.
To judge whether or not the print density of every inch (600 dots) in the
main scanning direction surpasses 50%, it counts the dots in 8 areas
(for 8 inches) every 75 bytes (600 dpi x 1 inch/8) after the line start. If the
print duty in any area surpasses 50%, the circuit notifies split printing to
the swath data conversion circuit. It further separates and counts odd-
and even-numbered slices in each area in order to clarify the number of
dots for split printing. When dots in all areas for a swath are counted,
odd- and even-numbered slices are totaled.
When the counting for a swath is finished, if both slices total 0, it notifies
the ESC command adding circuit to activate white skip operation and
clears the sub scan 600 dpi data buffer.
9) Swath data conversion circuit
This circuit reads data by 1-bit increments from the discrete address of
the sub scan 600 dpi data buffer and converts them into data of a slice.
When split printing is instructed from the printing dot calculation circuit,
it converts even-numbered slices for the first time. When conversion
completes, it creates odd-numbered slices without clearing the sub scan
600 dpi data buffer.
10) ESC command adding circuit
It adds a command line and a parameter to the printing data when a
print command is sent. Then sends a paper feed command for white
skip and a paper deliver command for after a single page printing.
11) IEEE1284 controller
It sends commands to, receives responses from and sends printing com-
mands and data to IEEE1284 interface of Hurricane.
12) Command buffer
It provides a buffer of 64 bytes to send commands from Fax Engine to
the printer (Hurricane). The actual buffer is located in the DRAM to keep
down the number of gates.
Therefore, equipped with a data path to the memory access arbiter and
an address controller to realize the buffer.
13) Response buffer
It provides a buffer of 1024 bytes to receive responses from the printer
(Hurricane) to Fax Engine. The actual buffer is located in the DRAM as
with the command buffer.
Also equipped with a data path to the memory access arbiter and an
address controller to realize the buffer.
5 � 11
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
D-R265SE
D-R265SE
Quick Start

$4.99
Current Parse Time: 0.090 s with 42 queries. Queries took 0.010865