1-2-l 1. Color Reproduction Adjustment
When adjustment is off, the color restoration will be poor.
SubjectColor bar chart standard picture frame
Measurement pointVIDEO output terminal (5552-l)
Vectorscope,
Measuring instrument
IIColor bar chart standard picture frameI
Adjustment pageF
OA IB-Y HUE)
OB (R-Y HUEj
Adjustment address
2F (B-Y GAIN)
32 (R-Y GAIN)
All color luminance points should settle with
Specified value
Iin each color reoroduction frame
Note : Make this adjustment after first performing the ?Entry of Auto White Balance Reference Data?.
Adjusting method :
Set the iris to fully open and display the color bar on the reference screen.
Sequence PageAddressDataProcedureConditions
160001Release the protect.
261406Press the PAUSE button after setting the data.
361301Press the PAUSE button after setting the data.
4 161 03 IOOIP ress the PAUSE button after setting the data.II
5601OFPress the PAUSE button after setting the data.
6F10FlPress the PAUSE button after setting the data.
7F63F6Press the PAUSE button after setting the data.
8FOAChange each data, set the color restoration for each color
OBbrightness point, and press the PAUSE button for each
2Faddress.
32
B-Y
B-Y
Direction of the Movements of the
Fig. B-l-8.Adjustment Address and Luminance Point
6-l 6 |