3-1-2. Precautions on Adjusting3-1-3. Adjusting Connectors
1) The adjustments of this unit are performed in the Some of the adjusting points of the video section are concentratedVTR mode
or camera mode.at VC-214 board CN910. Connect the measuring instruments via
To set to the VTR mode, set the power switch to OPLAthe CPC-7 jig (J-6082-382-A). YER� orThe following table lists the pin
set the OForced VTR Power ON mode� using the adjustmentnumbers and signal names of CN910.
remote commander (Note 1).Pin No.Signal NamePin No.Signal Name
To set to the Camera mode, set the power switch to OCAMERA�
or set the OForced Camera Power ON mode� using the1LANC SIG9RF AGC OUT
adjustment remote commander (Note 2).2XCPC IN10REC RF
After completing adjustments, be sure to exit the OF3 orced IR VIDEOVTR11RF SWP
Power ON Mode� or OForced Camera Power ON Mode�. (Note 3)4AFC F012CAP FG
2) By setting the OForced VTR Power ON mode� or OForced5BPF MONI13EVF BL
Camera Power ON mode�, the video section can be operate6PB RF14EVF BL 4.75V
even if even if the front panel block (MA-353 board, power
switch, microphone unit) has been removed. When removing7RF AGC IN15VCO
the front panel block disconnect the following connector8REG GND.16EVF VG
1. VC-214 board CN903 (20P 0.5mm)
3) The lens block (CD-209 board) and VL-25 board need not beTable 5-3-1.
connected except during battery end adjustment. To remove,
disconnect the following connectors.
1. VC-214 board CN501 (16P, 0.5mm)
2. VC-214 board CN551 (24P, 0.5mm)CN910
3. VL-25 board CN151 (8P, 0.5mm)
4) Cabinet (R) (Camera function switch (CF-58 board), LCD1
block, viewfinder) need not be connected. But removing the16
cabinet (R) (removing the VC-214 board CN911) means
removing the lithium 3V power supply (CF-58 board BH001),
data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If the cabinet (R) has
been removed, the self-diagnosis data, data on history of use
(total drum rotation time etc. ) will be lost. Before removing,
note down the self-diagnosis data and data on history use (data
of page: 2, address: A2 to AA). (Refer to the OService Mode�
for the data on the history use.) To remove the cabinet (R),
disconnect the following connectors.Screw driver (�)
1. VC-214 board CN911 (50P, 0.5mm)
2. DD-117 board CN933 (10P, 1.0mm)
Note 1:Setting the OForced VTR Power ON� mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.Cover
The above procedure will enable the VTR power to be turned
on with the front panel block removed.Fig. 5-3-1.
After completing adjustments, be sure to exit the OForced VTR
Power ON mode�.
Note 2:Setting the OForced Camera Power ON� mode (Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the front panel block removed.
After completing adjustments, be sure to exit the OForced
Camera Power ON mode�.
Note 3:Exiting the OForced Power ON� mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
5-30 |