3.SELF-DIAGNOSIS CODE TABLE
Self-diagnosis Code
BlockDetailedSymptom/StateCorrection
FunctionCode
Repaired by:
C2300Non-standard battery is used.Use the info LITHIUM battery.
C2100Condensation.Remove the cassette, and insert it again after one hour.
C2200Video head is dirty.Clean with the optional cleaning cassette.
C3110LOAD direction. Loading does not
complete within specified timeLoad the tape again, and perform operations from the beginning.
C3111UNLOAD direction. Loading does not
complete within specified timeLoad the tape again, and perform operations from the beginning.
C3120T reel side tape slacking when unloading.Load the tape again, and perform operations from the beginning.
C3121Winding S reel fault when counting theLoad the tape again, and perform operations from the beginning.
rest of tape.
C3122T reel fault.Load the tape again, and perform operations from the beginning.
C3123S reel fault.Load the tape again, and perform operations from the beginning.
C3124T reel fault.Load the tape again, and perform operations from the beginning.
C3130FG fault when starting capstan.Load the tape again, and perform operations from the beginning.
C3140FG fault when starting drum.Load the tape again, and perform operations from the beginning.
C3142FG fault during normal drum operLoad the taations.pe again, and perform operations from the beginning.
C3110LOAD direction loading motor time-Remove the battery or power cable, connect, and perform
out.operations from the beginning.
UNLOAD direction loading motorRemove the battery or power cable, connect, and perform
C3111time-out.operations from the beginning.
T reel side tape slacking whenRemove the battery or power cable, connect, and perform
C3220unloading.operations from the beginning.
Winding S reel fault when counting theRemove the battery or power cable, connect, and perform
C3221rest of tape.operations from the beginning.
C3222T reel fault.Remove the battery or power cable, connect, and perform
operations from the beginning.
C3223S reel fault.Remove the battery or power cable, connect, and perform
operations from the beginning.
C3224T reel fault.Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
C3230FG fault when starting capstan.operations from the beginning.
Remove the battery or power cable, connect, and perform
C3240FG fault when starting drumoperations from the beginning.
FG fault during normal drumRemove the battery or power cable, connect, and perform
C3242operationsoperations from the beginning.
Inspect the lens block focus reset sensor (Pin 7 of CN201 of VC-
E6100Difficult to adjust focus220 board) when focusing is performed when the control dial is
(Cannot initialize focus.)rotated in the focus manual mode, and the focus motor drive circuit
(IC503 of VC-220 board) when the focusing is not performed.
Inspect the lens block zoom reset sensor (Pin @1 of CN201 of VC-
E6110Zoom operations fault220 board) when zooming is performed when the zoom lens is
(Cannot initialize zoom lens.)operated and the zoom motor drive circuit (IC503 of VC-220 board)
when zooming is not performed.
Steadyshot function does not work well.Inspect pitch angular velocity sensor (SE2501 of MR-41 board)
E6200(With pitch angular velocity sensor outputperipheral circuits.
stopped.)
Steadyshot function does not work well.
E6201(With yaw angular velocity sensor outputInspect yaw angular velocity sensor (SE2500 of MR-41 board)
stopped.)peripheral circuits.