1-3. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, Check that the
specified values of O27/36MHz Origin Oscillation Adjustment�, OS
VIDEO OUT Y level Adjustment� and OS VIDEO OUT C level
Adjustment� of OVIDEO SYSTEM ADJUSTMENT� are satisfied.
1. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
SubjectNot required
Measurement PointDisplay data of page 1
Measuring Instrument Adjustment remote commander
Adjustment PageF
Adjustment Address47, 48
Specified Value88 to 8C during IRIS OPEN
15 to 19 during IRIS CLOSE
Note:Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Display data
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 47 and 48.)
3) Select page: 6, address: 02, and check that the data is O01�.
4) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1) Select page: 0, address: 03, and set data: 03.
2) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
3) Select page: 1, and check that the display data (Note) during
IRIS OPEN satisfies the specified value.
4) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
5) Select page: 1, and check that the display data during IRIS
CLOSE satisfies the specified value.
Processing after Completing Adjustments
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 0, address: 03, and set data: 00.
5-21 |