DCR-TRV240E/TRV340E
2-2. DIGITAL8 MODE2-2-3. OVERALL TAPE PATH CHECK
Note1: Before performing the adjustments, check the data of page: 0,
address: 10 is O00�. If not, set data: 00 to this address.1. Recording of the tape path check signal
Note2: < >: DCR-TRV240E, [ ]: DCR-TRV340E1) Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2-2-1. HOW TO ENTER RECORD MODE WITHOUT2) Connect the adjustment remote commander to the LANC jack.
CASSETTE3) Turn the HOLD switch of the adjustment remote commander
1) Connect the adjustment remote commander to the LANC jack.to the ON position.
2) Turn the HOLD switch of the adjustment remote commander4) Set to the camera recording mode.
to the ON position.5) Select page: 3, address: 1C, set data: 5D, and press the PAUSE
3) Close the cassette compartment without the cassette.button of the adjustment remote commander.
4) Select page: 3, address: 01, and set data: 0C, and press the6) Record for several minutes.
PAUSE button of the adjustment remote commander7).Release the camera recording mode.
(The mechanism enters the record mode automatically8) Select pag.)e: 3, address: 1C, set data: 00, and press the PAUSE
Note:The function buttons becomes inoperable.button.
5) To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button. (Whenever you want to quit2. Tape path check
the record mode, be sure to quit following this procedure.)1) Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2-2-2. HOW TO ENTER PLAYBACK MODE WITHOUT2) Connect the adjustment remote commander to the LANC jack.
CASSETTE
1) Connect the adjustment remote commander to the LANC jack.3) Turn the HOLD switch of the adjustment remote commander
to the ON position.
2) Turn the HOLD switch of the adjustment remote commander4) Connect an oscilloscope to VC-276 board CN1108 via the CPC-
to the ON position.
13 jig (J-6082-443-A).
3) Close the cassette compartment without the cassette.Channel 1: VC-276 board, CN1108 Pin qh (Note)
4) Select page: 3, address: 01, and set data: 0B, and press theExternal trigger: VC-276 board,qd CN1108 Pin
PAUSE button.
Note:Connect a 75& resistor between Pins qh of CN1108 and 6
(The mechanism enters the playback mode automatically(GND)..)
Note:The function buttons becomes inoperable.5) Select page: <2>[7], address: <4D>[62], and set data: <40>[01].
5) To quit the playback mode, select page: 3, address: 01, set data:(Note2)
00, and press the PAUSE button. (Whenever you w6)ant to quitPlayback the tape path check signal.
the playback mode, be sure to quit following this pr7) Select page: 3, address: 26, and set data: 31.ocedure.)
8) Select page: 3, address: 33, and set data: 08.
9) Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, perfO2-1-2. Torm APE PATH ADJUSTMENT� of
O2-1. HI8/STANDARD 8mm MODE�.
10) Select page: 3, address: 26, and set data: 00.
11) Select page: 3, address: 33, and set data: 00.
12) Select page: <2>[7], address: <4D>[62], and set data: 00.
(Note2)
Must be flat
Pin qh
Pin qd
Fig. 5-2-2.
5-41 |