DSC-P3
14. CCD White Defect Compensation
ModeCAMERA
SubjectNot required
Measurement PointDisplayed data of page: 6,
address: 55
Measuring InstrumentAdjusting remote commander
Adjustment Page7
Adjustment Address88 to FF
Note 1:Check that the data of page: 6, address: 02 is O00�.
If not, turn the power of unit OFF/ON.
Note 2:The OCCD White Defect Compensation� should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address DataProcedure
100101
Perform OData setting during
2camera system adjustments�.
(Refer to page 5-15)
3FDE1E Press PAUSE button.
4FE313Press PAUSE button.
56018B Press PAUSE button. (Note 3)
6602Check the data changes to O01�.
Check the data.
765500 to 7F: Normal
80 to FF: Defective
860100Press PAUSE button.
9FDE0FPress PAUSE button.
10FE360Press PAUSE button.
1160187Press PAUSE button.
12602Check the data changes to O01�.
13655Check the data is O00�.
Note 3:The adjustment data will be automatically input to
page: 7, address: 88 to FF.
Processing after Completing Adjustment:
Order Page Address DataProcedure
160100Press PAUSE button.
Release the data setting
2performed at step 2 . (Refer
to page 5-15)
300100