2-1. DVA-A1100
Check Procedure4. Click the [Exit] button on the display of PC2.
5. After clicking the [Stop] button on the display of PC1
1. Click the [Start] button on the display of PC1.to stop the data output, click the [Exit] button.
The OTime Code� window appears on the display, andn
the TC value starts counting from [00 : 59 : 50 : 00].After starting the data output in PC2, carefully fetch
nthe data in PC1. Incorrect operation could cause
The TC value is the value set in the setting exampleproblems.
given in OPreparation�.
2. Click the [Start] button on the display of PC2.
The Time Code window appears on the display and the
TC value that is being input is displayed.
Check to see that the display changes when the TC
value reaches the value as sown below.
TC valueCheck item
00 : 59 : 59 : 29CLOSE indication ? OPEN indication
01 : 00 : 10 : 00OPEN indication ? CLOSE indication
n
The TC value is the value set in the setting example
given in OPreparation�.
3. [OPEN indication ? CLOSE indication] appears, the
OTime Code� window is closed about four seconds
later, and the check result is displayed.
Spec. :
Data offset : Either 13264, 13268, 13272, 13276,
or 13280
Text box : No error indication
2-6 (E)DVA-A1100/P1100/R1100 |